34
on the terminal block. Tighten the screw securely.
7. Attach the red and black power cord conductors to
the outer brass-colored terminals on the terminal
block.
Do not make a sharp bend or crimp
wiring/ conductor at the connections.
8. Tighten the screws securing the cord restraint firmly
against the power cord.
9. Tighten the strain relief nut securely so the strain
relief does not turn.
10.Reinstall the terminal block access cover.
INSTALLATION
1. GAS CONNECTION
(Gas dryers only)
a. Remove the shipping cap from gas pipe at the
rear of the dryer.
NOTE: DO NOT
connect the dryer to L.P. gas
service without converting the gas valve. An L.P.
conversion kit (P/N 131776600) must be
installed by a qualified gas technician.
b. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or
approved pipe from gas supply line to the 3/8
inch (0.96 cm) pipe located on the back of the
dryer. Use a 1/2 inch to 3/8 inch (1.27 cm to
0.96 cm) reducer for a connection. Apply an
approved thread sealer that is resistant to the
corrosive action of liquefied gases on all pipe
connections.
c. Open the shutoff valve in the gas supply line.
d. Test all connections by brushing on a soapy water
solution.
NEVER TEST FOR GAS LEAKS
WITH AN OPEN FLAME.
2. Connect the exhaust duct to outside exhaust
system. Use duct tape to seal all joints.
3. With the dryer in its final position, adjust one or
more of the legs until the dryer is resting solid on
all four legs. Place a level on top of the dryer.
THE
DRYER MUST BE LEVEL AND RESTING SOLID
ON ALL FOUR LEGS.
Turn the lock nuts on each
of the four legs up toward the base of the dryer and
snug with a 1/2 inch open end wrench.
4. Plug the power cord into a grounded outlet. NOTE:
Check to ensure the power is off at circuit breaker/
fuse box before plugging the power cord into the
outlet.
5. Turn on the power at the circuit breaker/fuse box.
Before operating the dryer, make sure
the dryer area is clear and free from combustible
materials, gasoline, and other flammable vapors. Also
see that nothing (such as boxes, clothing, etc.)
obstructs the flow of combustion and ventilation air.
6. Run the dryer through a cycle check for proper
operation.
NOTE:
On gas dryers, before the burner will light,
it is necessary for the gas line to be bled of air. If
the burner does not light within 45 seconds the first
time the dryer is turned on, the safety switch will
shut the burner off. If this happens, turn the timer
to "OFF" and wait 5 minutes before making another
attempt to light.
7. If your dryer does not operate, please review the
"Avoid Service Checklist" located in your Owner's
Guide before calling for service.
8. Place these instructions in a location near the dryer
for future reference.
NOTE:
A wiring diagram is located inside the dryer
console or under the top panel.
REPLACEMENT PARTS
If replacement parts are needed for your dryer, contact
the source where you purchased your dryer.
Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.
Destroy the carton and plastic bags after
the dryer is unpacked. Children might use them for
play. Cartons covered with rugs, bedspreads, or plastic
sheets can become airtight chambers causing
suffocation. Place all materials in a garbage container
or make materials inaccessible to children.
The instructions in this manual and all
other literature included with this dryer are not meant
to cover every possible condition and situation that
may occur. Good safe practice and caution
MUST
be
applied when installing, operating and maintaining any
appliance.
Содержание 27" Dryers
Страница 10: ...10 ...
Страница 11: ...11 SAMPLE WIRING DIAGRAM FOR ELECTRIC MODELS WITH ELECTRONIC MOISTURE SENSOR CONTROLS ...
Страница 12: ...12 ...
Страница 13: ...13 SAMPLE WIRING DIAGRAM FOR GAS MODELS WITH ELECTRONIC MOISTURE SENSOR CONTROLS ...
Страница 80: ...80 ...