EXHAUST DIRECTION
All dryers shipped from the factory are set up for rear
exhausting. However, on electric dryers, exhausting can
be to the right or left side of the cabinet or the bottom
of the dryer. On gas dryers, exhausting can be to the
right side of the cabinet or the bottom of the dryer.
Directional exhausting can be accomplished by
installing Exhaust Kit, P/N 131456800, available
through your parts distributor. Follow the instructions
supplied with the kit.
EXHAUST DUCT LOCATING DIMENSIONS
GAS SUPPLY REQUIREMENTS
Replace copper connecting pipe that
is not plastic-coated. Stainless steel or plastic-
coated brass MUST be used.
1. Installation
MUST
conform with local codes, or in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1 (latest edition) or in
Canada, the current CAN/CGA B149.
2. The gas supply line should be of 1/2 inch (1.27 cm)
pipe.
3. If codes allow, flexible metal tubing may be used
to connect your dryer to the gas supply line. The
tubing
MUST
be constructed of stainless steel or
plastic-coated brass.
4. The gas supply line
MUST
have an individual
shutoff valve.
5. A 1/8 inch (0.32 cm) N.P.T. plugged tapping,
accessible for test gauge connection,
MUST
be
installed immediately upstream of the gas supply
connection to the dryer.
6. The dryer
MUST
be disconnected from the gas
supply piping system during any pressure testing
of the gas supply piping system at test pressures in
excess of 1/2 psig (3.45 kPa).
7. The dryer
MUST
be isolated from the gas supply
piping system during any pressure testing of the
gas supply piping system at test pressures equal to
or less than 1/2 psig (3.45 kPa).
LOCATION OF YOUR DRYER
DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside
weather conditions.
2. In an area where it will come in contact with curtains,
drapes, or anything that will obstruct the flow of
combustion and ventilation air.
3. On carpet. Floor
MUST
be solid with a maximum
slope of 1 inch (2.54 cm).
INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or
closet,
MUST
be exhausted outdoors.
2. No other fuel burning appliance shall be installed in
the same closet as the Gas dryer.
3. Your dryer needs the space around it for proper
ventilation.
DO NOT INSTALL YOUR DRYER IN A CLOSET
WITH A SOLID DOOR.
4. A minimum of 120 square inches (774.2 square cm)
of opening, equally divided at the top and bottom of
the door, is required. Air openings are required to
be unobstructed when a door is installed. A louvered
door with equivalent air openings for the full length
of the door is acceptable.
MINIMUM INSTALLATION CLEARANCES (Inches)
FRONT
SIDES REAR TOP
Alcove or Under
counter 0 (0 cm) 0 (0 cm)0 (0 cm)15 (38.1 cm)
Closet 1 (2.54 cm)0 (0 cm)0 (0 cm)15 (38.1 cm)
Closet door ventilation required: 2 louvered openings
each 60 square inches (387 square centimeters) 3
inches (7.6 cm) from bottom and top of door.
THIS DRYER MUST BE EXHAUSTED OUTDOORS.
5. The following illustrations show minimum clearance
dimensions for proper operation in a recess or closet
installation.
SAME AS OTHER SIDE
(9.5 cm)
4 3/8"
(11 cm)
5 7/8"
(15 cm)
13 1/2"
(34 cm)
3 3/4"
(9.5 cm)
3 3/4"
(9.5 cm)