![Electrolux 10 GN 1/1 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/electrolux/10-gn-1-1/10-gn-1-1_user-manual_17720031.webp)
31
Anom-
aly
Type of
anomaly
Description
Possible causes
Actions
FSnr
Warning
Cooling fan issue
• Inlet air filter dirty
• Cooling fan failure
• Clean inlet air filter;
• Check with a thin strip of paper whether a
consistent air flow can be detected at the
cooling air inlet: if not, call Service.
FUXX
(XX = 00
- 17)
Stops oven
Upper cavity motor
failure
Diagnostic according to
error number (from 00 to 17)
displayed.
Switch the oven OFF/ON;
If the error persists, manually clean the oven
cavity and call Service.
GbbU
Stops the
boiler
Boiler gas burner
locked
• Air in gas supply;
• Gas supply is closed;
• Issue with the electric
supply of the burner
system;
• Burner system internal
failure;
The oven can continue to work both in convec-
tion and ISG mode.
To recover full boiler functionality:
• Switch the oven OFF/ON.
• If the error occurs at the cycle start, call
Service.
• If the error occurs after 5 ignition attempts:
1. check the gas supply main valve is open;
2. reset the error and attempt new cycle;
3. if the error persists, switch OFF/ON the
oven and attempt new cycle again;
4. if the error persists, call Service
GbCd
Cycle
paused
Cavity lower burner
locked
• Air in gas supply;
• Gas supply is closed;
• Issue with the electric
supply of the burner
system;
• Burner system internal
failure;
The oven will not operate until restoring the
burner functionality.
To recover the functionality:
• Switch the oven OFF/ON.
• If the error occurs at the cycle start, call
Service.
• If the error occurs after 5 ignition attempts:
1. check the gas supply main valve is open
2. reset the error and attempt new cycle
3. if the error persists, switch OFF/ON the
oven and attempt new cycle again;
4. if the error persists, call Service
GbCU
Cycle
paused
Cavity upper burner
locked
• Air in gas supply;
• Gas supply is closed;
• Issue with the electric
supply of the burner
system;
• Burner system internal
failure;
The oven will not operate until restoring the
burner functionality.
To recover the functionality:
• Switch the oven OFF/ON.
• If the error occurs at the cycle start, call
Service.
• If the error occurs after 5 ignition attempts:
1. check the gas supply main valve is open
2. reset the error and attempt new cycle
3. if the error persists, switch OFF/ON the
oven and attempt new cycle again;
4. if the error persists, call Service
GrCo
Stops
cleaning
cycle
Grease collector valve
opened
Misuse
Ensure to close the grease collector drain valve
before restarting the cleaning cycle.
HdXX
(XX =
01-26)
Stops oven
Valves/pumps
activations
Diagnostic according to
error number (from 01 to 26)
displayed.
Switch the oven OFF/ON;
If the error persists, follow instructions displayed.
If the error persists, manually clean the oven
cavity and call Service.
HFnI
Stops
humidifier
Humidifier not working
• Water missing;
• ISG circuit obstruction.
The oven has detected a problem with the
humidifier (ISG). It could be possible to cook in
convection mode only.
Verify the water supply valve is fully open and
the water filler has no obstructions. Clean it if
needed.
If the problem persists, call Service.
Содержание 10 GN 1/1
Страница 1: ...Electrical and Gas Oven Combi DIGITAL EN User manual Original instructions 0595403Z01 2020 01 ...
Страница 36: ......
Страница 37: ......
Страница 38: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www professional electrolux com ...