69
5
• Close the door.
• Go down to ”Calibration of level sensor”
• Press ”Select”
Calibration of level control system
• Press ”Open” to fill water until the water reaches the botton of the inner
drum where the ruler is placed.
• Press ”OK”
• Enter the value read on the ruler in RU units (The first setting is 0=level in
drum.
• Press ”OK”
• Press ”Open” to fill more water.
• Press ”OK”
• Enter the value read on the ruler in RU units. (If wrong value is entered, press
”CLR”. Enter new value.
• Press ”OK”
• Enter another three values so that it will be five different totally.
• When all values have been entered, press ”Save”
LEVEL CALIBRATION
FILL WATER TO
DESIRED LEVEL
LEVEL:
0 SCU
OPEN
OK
5