Calibration of level control system
1
CLS 7.jpg
2
IMG 0012.jpg
Calibration of level control system
The level control system can be individually and manually calibrated. The
calibration starts at the level at the bottom of the inner drum. The calibra-
tion can be made up to 250 mm from the bottom of the inner drum.
A ruler is supplied with the machine where the water level above the inner
drum can be read.
• Place the ruler on the bottom of the inner drum, equally between two lifters
and front and rear gables. Rotate the drum so that the ruler is totally vertical
and assure that the three pins of the ruler fit in the holes of the inner drum.
• Push the scale to the bottom of the drum and tighten the nuts.
• Close the door.