4 Evacuation system
4.1
Air principle
Note!
It is very important that the machine gets enough fresh air in order to get the best drying result.
4.1.1
Electric-, Steam- and Gas heated machines
The fan creates low pressure in the machine, drawing air into the drum via the heating unit. The heated air passes
through the garments and the drum holes and flows out through the filter positioned below the drum. The air is then
evacuated through the fan and exhaust system.
fig.X00730
4.1.2
Machines with heat pump
The fan creates air flow in the machine, drawing air into the drum via the heating unit. The heated air passes through
the garments and the drum holes and flows out through the first filter drawer and continues through the second spe-
cial filter just underneath. The special filter is necessary in machines with heat pump in order to protect the heat
pump to get clogged by lint. When the air has passed the two filters it recirculates back into the drum.
fig.X00729
Ventilating the room
When the machine is in operation, the room temperature increases. Due to this, the room must have sufficient
ventilation.
All sources introducing heat into the same room requires to be considered when dimensioning the ventilation. Heat
sources could for example be: more tumble dryers, drying cabinets, washers, ironers, radiators, etc. The combination
of several sources for heat introduction leads to an increased need for ventilation flow. Other factors may also influ-
ence the needed ventilation flow, such as climate zone, building parameters, room size, etc. For assistance with di-
mensioning necessary ventilation needs, contact authorized ventilation technician.
Содержание TD6-20LAC
Страница 1: ...Installation manual Tumble dryer TD6 20LAC Type N2 Original instructions 438905920 GB IE 2022 11 30 ...
Страница 2: ......
Страница 4: ...Contents The manufacturer reserves the right to make changes to design and component specifications ...
Страница 25: ...Installation manual 25 Demount the lower side panel 3x fig X00979E Disconnect the NTC sensor fig X01226B ...
Страница 51: ......
Страница 52: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...