24
Installation manual
4.6
Adjusting the air flow (not valid for tumble dryers with heat pump)
Adjusting the air flow may only be carried out by authorized personnel.
It is important that the machine has the correct air volume compared to each machines effect. If the air flow is below
the minimum, the machine will be forced to switch the heating off which will result in longer drying time.
An air flow above needed is unnecessary and can result in a cold laundry room and noise from the piping and outlet.
In extreme causes this can result in longer drying time.
The machine is pre-set for an optimal air flow with up to 15 m equivalent pipe length. (For default settings from fac-
tory, check the label attached on the damper.) For piping systems which deviate from pre-set pipe length it is neces-
sary to adjust the machine according to the following instructions.
• Remove the filter drawer and demount the front panel.
• Demount the rear panel.
6x
fig.X00731A
Содержание TD6-20LAC
Страница 1: ...Installation manual Tumble dryer TD6 20LAC Type N2 Original instructions 438905920 GB IE 2022 11 30 ...
Страница 2: ......
Страница 4: ...Contents The manufacturer reserves the right to make changes to design and component specifications ...
Страница 25: ...Installation manual 25 Demount the lower side panel 3x fig X00979E Disconnect the NTC sensor fig X01226B ...