Installation manual
41
7.6.4
Price reduction (2K)
By maintaining an activated (high) signal on connection 5 ("Price red"), the price of the program can be reduced. This
function has a number of uses, including providing reductions during a specific period of the day. Whilst the signal re-
mains active (high), the price of the program is reduced (or the time is increased on time programs), by the percent-
age entered in the price programming menu.
fig.7441
7.7
Option
7.7.1
External connection 100 mA
A special connection terminal is located on the connection console.
This connection can be used as external control of a fan.
The terminal for external control is equipped with 220–240V max.100 mA and is intended solely for the operation of a
contactor.
Max. connection 100 mA.
Gnd. must not be used for earthing of external board.
X1
X2 Gnd.
fig.7154
Содержание TD6-20
Страница 1: ...Installation manual Tumble dryer TD6 20 Type N2 Original instructions 438905910 GB IE 2022 11 28 ...
Страница 2: ......
Страница 28: ...28 Installation manual Demount the lower side panel 3x fig X00979E Disconnect the NTC sensor fig X01226B ...
Страница 59: ......
Страница 60: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...