22
Installation manual
Note!
The machine should be positioned so that there will be enough space for working, both for the user and
service personnel.
Respecting the given recommendations will provide easy access for maintenance and service operations.
In case of space limitations, it is possible to install machines without respecting to the given recommendations. If so,
keep in mind that it might be necessary to disconnect and move other machines to be able to reach and perform
service on affected machine.
4.5
Drain connection (only for machines with heat pump)
Connect the pipe (A) that is enclosed with the machine to the drain on the heat pump unit.
Connect a drain hose to the pipe (A).
A
fig.X00695
Note!
The drain hose (A) must be positioned over the water level in the floor drain.
The drain must be lower than the drain outlet from the heat pump unit. If not the water will flow back into the
machine. Adjust with the feet.
The hose shall hang in a gentle arc.
4.6
Mechanical installation
Level the machine with the feet of the machine. The maximum height adjustment of the feet is 15 mm.
Note!
It is important that the machine stand steady on all four feet and not directly on the wheels. The wheels must
only be used when moving the machine.
4x
fig.X00694
Содержание TD6-20
Страница 1: ...Installation manual Tumble dryer TD6 20 Type N2 Original instructions 438905910 GB IE 2022 11 28 ...
Страница 2: ......
Страница 28: ...28 Installation manual Demount the lower side panel 3x fig X00979E Disconnect the NTC sensor fig X01226B ...
Страница 59: ......
Страница 60: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...