Installation manual
7
2.2
Technical data
Capacity:
kg of laundry
10
Drainage capacity:
g/min*
55
Electrical connection:
220-240V 1 AC
50-60 Hz
Traditional threaded fuse:
A
13A
Automatic fuse:
A
13A
Power:
kW
2.6
Hanging length:
meters
20
Weight:
kg
205
Sound pressure level:
A-weighted emission sound pressure level
dB (A)
<57
Average heat emission per drying cycle used
to assess ventilation need**:
kW
1.1
* 6.5 kg dry weight cotton, 50% residual moisture.
** For assistance with dimensioning necessary ventilation needs, contact authorized ventilation technician. For suffi-
cient ventilation all sources introducing heat need to be taken into account plus all other parameters effecting the
ventilation need. Climate zone, building parameters, room size, etc.
Connections
Connection, condensation
Plastic hose dim
⌀
10 mm. 3 m hose included.
Heat pump
Type of refrigerant
R407C
Amount of refrigerant
kg
1.0
Fluorinated greenhouse gases
This product contains fluorinated greenhouse gases.
GWP: 1430
CO
2
equivalent: 1.43 t
Leak test: 28 bar
Hermetically sealed.
Energy consumption and drying times
Drying of centrifuged laundry **)
Programs:
Normal drying
Energy consumption:
kWh / kg of laundry
0.31
Energy dried water:
kWh / liter
0.62
Drying time ***):
minutes
60
**) The values may vary depending on:
• speed during spin cycle
• temperature, humidity in the room
• air circulation in the room (supply air, exhaust air)
• settings in the parameter list regarding moisture sensor and time for the SUN program
The values relate to a 6 kg load with 50% residual moisture.
***) The drying cabinet reconditions 5 minutes after the textiles have dried
Содержание DC6-10HP
Страница 1: ...Installation manual Drying Cabinet DC6 10HP Original instructions 427001232 EN 2022 03 01 ...
Страница 2: ......
Страница 4: ......
Страница 23: ......
Страница 24: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...