-16 

 

 

EPS-HDM1004ECO

 

Encoder Modulator User Manual 

Wall 

It can be covered with wallpaper, or brightness less paint. 

Fire Protection 

Fire alarm system and extinguisher 

Power 

Requiring  device  power,  air-conditioning  power  and  lighting 
power  are  independent  to  each  other.  Device  power  requires 
AC  110V±10%,  50/60Hz  or  AC  220V±10%,  50/60Hz. Please 
carefully check before running. 

2.5 Grounding Requirement 

 

All  function  modules’  good  grounding  is  the  basis  of  reliability  and  stability  of  devices. 

Also,  they  are  the  most  important  guarantee  of  lightning  arresting  and  interference 

rejection. Therefore, the system must follow this rule. 

 

Grounding  conductor  must  adopt  copper  conductor  in  order  to  reduce  high  frequency 

impedance, and the grounding wire must be as thick and short as possible. 

 

Users  should  make  sure  the  2  ends  of  grounding  wire  well  electric  conducted  and  be 

antirust. 

 

It is prohibited to use any other device as part of grounding electric circuit 

 

The area of the conduction between grounding wire and device’s frame should be no 

less than 25 mm

2

 

Chapter 3 WEB NMS Operation

 

Users can only control and set the configuration in computer by connecting the device to 

web  NMS  Port.  User  should  ensure  that  the  computer’s  IP  address  is  different  from  this 

device’s IP address; otherwise, it would cause IP conflict. 

3.1 Login 

The default IP address of this device is 192.168.0.136.   

Connect the PC (Personal Computer) and the device with net cable, and use ping command 

Содержание EPS-HDM1004ECO

Страница 1: ...EPS HDM1004ECO Encoder Modulator User Manual ...

Страница 2: ...and standards Directory CHAPTER 1 INTRODUCTION 1 1 1 PRODUCT OVERVIEW 1 1 2 KEY FEATURES 1 1 3 SPECIFICATIONS 1 1 4 PRINCIPLE CHART 2 CHAPTER 2 INSTALLATION GUIDE 3 2 1 GENERAL PRECAUTIONS 3 2 2 POWER PRECAUTIONS 4 2 3 DEVICE S INSTALLATION FLOW CHART ILLUSTRATED AS FOLLOWING 4 2 4 ENVIRONMENT REQUIREMENT 4 2 5 GROUNDING REQUIREMENT 5 CHAPTER 3 WEB NMS OPERATION 5 3 1 LOGIN 5 3 2 OPERATION 6 CHAPT...

Страница 3: ...中文 中文 中文 English ﺍﻟﻌﺮﺑﻴﺔ ไทย िह दी िह दी िह दी िह दी руская ﺍﺭﺩﻭ for more languages please consult us 4 HDMI input MPEG 4 AVC H 264 Video encoding MPEG1 Layer II LC AAC HE AAC audio encoding format and AC3 Pass Through and support audio gain adjustment 2 groups of multiplexing modulating output channels 2 DVB T RF out Support64 IP inputs 2 MPTS IP output over UDP and RTP RTSP Support PID remapping...

Страница 4: ...SI table automatically Modulation DVB T RF out 2 RF DVB T out 2 carriers combined output Standard EN300 429 ITU T J 83A B MER 40db RF frequency 50 960MHz 1KHz step RF output level 25 1dBm 82 105 dbµV 0 1dBm Symbol Rate 5 0Msps 7 0Msps 1ksps stepping J 83A J 83B Constellation 16 32 64 128 256QAM 64 256 QAM Bandwidth 7M 6M Stream output RF output F type interface 2 IP MPTS output over UDP RTP RTSP 1...

Страница 5: ...put port GE 7 NMS Network management port Chapter 2 Installation Guide This section is to explain the cautions the users must know in some case that possible injure may bring to users when it s used or installed For this reason please read all details here and make in mind before installing or using the product 2 1 General Precautions Must be operated and maintained free of dust or dirty The cover...

Страница 6: ...t Item Requirement Machine Hall Space When user installs machine frame array in one machine hall the distance between 2 rows of machine frames should be 1 2 1 5m and the distance against wall should be no less than 0 8m Machine Hall Floor Electric Isolation Dust Free Volume resistivity of ground anti static material 1X107 1X1010 Grounding current limiting resistance 1M Floor bearing should be grea...

Страница 7: ...ng conductor must adopt copper conductor in order to reduce high frequency impedance and the grounding wire must be as thick and short as possible Users should make sure the 2 ends of grounding wire well electric conducted and be antirust It is prohibited to use any other device as part of grounding electric circuit The area of the conduction between grounding wire and device s frame should be no ...

Страница 8: ...lator s IP address in the browser s address bar and press Enter It displays the Login interface as Figure 1 Input the Username and Password Both the default Username and Password are admin and then click LOGIN to start the device setting Figure 1 3 2 Operation Summary Status When we login into encoder module it displays the status interface as Figure 2 Figure 2 User can click any item here to ente...

Страница 9: ... where to set Logo Caption QR Code parameters Figure 4 General settings for the Encoding program User can edit any item listed as needed The light will turn green if there is source inputting from module Otherwise the light will turn red Select to configure logo caption or QRcode Select program1 4 to apply the logo insertion or you can select all to apply all programs Click here to confirm the LOG...

Страница 10: ...EPS HDM1004ECO Encoder Modulator User Manual Figure 5 Enter your text here Put your caption anywhere Select the text color and background color Set when to show caption So do Logo and QRCode ...

Страница 11: ...ce where users can configure the TS output parameters TS Config Output TS X Clicking Output TS X it displays the interface where users can select the TS output carrier Figure 7 Clicking output TS 1 4 to set each output channel s programs general parameters and PID Put the QR code everywhere Browse and select the QRcode which has been created Input the QR code URL ...

Страница 12: ...en means current encoder stream locked To check current TS overflowing or not red color means current TS overflowing need reduce program To filter not filter the source CA information To enable disable the PID remapping To refresh the input program information To refresh the output program information Select one input program first and click this button to transfer the selected program to the righ...

Страница 13: ...d by clicking the program in the output area For example when clicking it triggers a dialog box Figure 9 where users can input new information Figure 9 TS Config General From the TS Config menu on up side of the webpage clicking General it displays the interface where users can enable PSI SI table out NIT insert and Character Encoding Figure 10 Figure 10 ...

Страница 14: ... it displays the interface where users can enable PID Pass through Figure 11 Figure 11 Parameters Modulator Clicking Modulator it displays the Modulator Configuration screen as Figure 12 EPS HDM1004ECO supports 2 DVB T RF out Here user can set modulation parameters such as level frequency and bandwidth etc Quickly Config Channel Config ...

Страница 15: ...O supports 2 TS to output in IP format through the DATA port Clicking IP Stream it displays the interface where to set IP out parameters Figure 13 Figure 13 When users click pen button it triggers a dialog box Figure 14 where users can set the corresponding channel configuration Channel Config ...

Страница 16: ...the TS out via ASI out System Network Clicking Network it displays the interface as Figure 15 where to set network parameters Figure 15 System Account Clicking Account it displays the screen as Figure 16 where to set the login account and password for the web NMS Both the current username and password are admin ...

Страница 17: ... Configuration Clicking Configuration it displays the screen as Figure 17 where to save restore factory setting backup load your configurations Figure 17 System Firmware Clicking Firmware it displays the screen as Figure 18 where to update firmware for the modulator ...

Страница 18: ...ime From the menu on left side of the webpage clicking Date Time it will display the screen as Figure 19 where to set date and time for the device Figure 19 System Log Clicking Log it displays the log interface as Figure 20 where to check or export the Kernel System log ...

Страница 19: ... 16 EPS HDM1004ECO Encoder Modulator User Manual Figure 20 ...

Страница 20: ...ries within tolerant range if it is necessary Checking all signal cables have been properly connected Frequently switching on off device is prohibited the interval between every switching on off must greater than 10 seconds Conditions need to unplug power cord Power cord or socket damaged Any liquid flowed into device Any stuff causes circuit short Device in damp environment Device was suffered fr...

Отзывы: