background image

J. Specifications

Model

BC – 1210

BC – 1215

BC - 1220

Output

Absorption Charge Voltage Selections

GEL : 14.2V     WET : 14.6V     CALCIUM-CALCIUM : 15.5V

Float Charge Voltage Selections

Yes

Yes

Yes

Battery Charger / Power Supply Selections

Yes

Yes

Yes

Maximum Output Charging Current (Continuous)

10A

15A

20A

Recommended Battery Capacity Range

40 – 100AH

60 – 150AH

80 - 200AH

Soft Start Bulk Charge

Battery Voltage to Trigger (cut-in) Soft Start
Bulk Charge Mode

<10.5V

Soft Start Bulk Charge Current (Current Limit)

5A

7.5A

10A

Line Regulation (180-260V) for Charging Current

<0.6%

Ripple and Noise (Peak to Peak)

100mV

100mV

150mV

Efficiency at Maximum Power

90%

87%

82%

Dual Bank Charging (Battery must be of same type)

No

Yes

Yes

Input

AC Voltage Range

180 – 260V 50Hz~

AC Current at Full Load

1.2A

1.8A

2.4A

Protection

Overload

90-110% Rated Output Current or 50% Rated Output Current (Soft
Charge)
Protection Type : Constant Current Limiting, recovers Automatically after
Fault Condition is Removed.

Short Circuit

Recovers Automatically After Fault Condition is Removed

Reverse Polarity

Car Blade Fuse

Over Temperature

Protection Type:Automatically de-rate Charge Current Until Zero or Shut
Down

OVP Output Over Voltage

Yes

Cooling

Cooling Method

Convection Cool

Thermostatic, Variable Speed Fan, Fan stops at
Float

Indicators

3 Stage Battery Charger / Power Supply Mode

Yes

Charge Phase Bulk / Absorption / Float

Yes

Fault Mode

Yes

AC Power

Yes

Fuses

AC Fuses at IEC AC Power Socket

T2A

T3.15A

T5A

DC Car Blade Fuse at Front Panel

20A

30A

30A

Accessories

Cable & Spare Fuses

Yes

Remote Temperature Sensor

Optional

Approvals

Safety : EN 60335

Yes

EMC : EN 55014

Yes

Others

Dimensions and Weight

160x61x173mm ; 1.3kg 160x61x173mm ; 1.4kg 160x61x207mm ; 1.6kg

Remarks

All values are based on the standard ambient temperature 25°C and pressure 0.1Mpa.

Rev. 1.5   03/2009

7673-2120-2522

Содержание BC-1210

Страница 1: ...attery Wear protective goggles and turn your face away when connecting or disconnecting the battery Never place the charger on top of a battery Never smoke use an open flame or create sparks near battery or charger during normal charging operation as batteries may give out explosive gas Do not charge batteries in an enclosure box in due to possible explosion of entrapped explosive gas Disconnect t...

Страница 2: ...election Slide Switch to set Charger to 3 Stage Charger or Power Supply Mode See Section G 3 Battery Type Selection Slide Switch to set charger for GEL Wet and Calcium Calcium type battery 4 Float Voltage Selection Slide Switch to set Float Charge voltage to 13 2 13 5V 13 8V 5 Charge Status LED Display Charger ON LED Green 3 Stage Charger Mode Red Power Supply Mode BULK LED Red Bulk Charging with ...

Страница 3: ...tery Charger Installation and Connection Observe the warnings safety precautions before connecting the charger Check battery condition fill up cells for wet battery clean battery posts Secure the battery charger in a well ventilated place make sure the mounting surface is flat The air intake is at the bottom and air outlet at the back Make sure both intake and outlet are not blocked Never place ch...

Страница 4: ...of same chemical make up and type to avoid over and under charging because only one setting of charging profile for both Two batteries are charged simultaneously and the battery with the lowest level gets most share of the current in the Bulk charge stage until it is up to the same voltage level of the second battery battery with higher initial level Both batteries will go to the Absorption and th...

Страница 5: ... is used to optimise charging over wide ambient temperature range Fix the temperature sensor optional accessory in a position on the battery which is not affected by other cooling or heating source Plug in the temperature sensor then switch on the charger to activate the temperature control function never plug in the sensor during charging Fig 4 ...

Страница 6: ...light does not come on even after 20 hours charging time Absorption light remains on all the time Wrong battery type Total battery capacity is too high for dual charging Battery temperature too high Battery is defective A load is connected to battery and charger is not in power supply mode Check charged battery label and change battery type selection to correct setting Check battery capacity or ch...

Страница 7: ... Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically After Fault Condition is Removed Reverse Polarity Car Blade Fuse Over Temperature Protection Type Automatically de rate Charge Current Until Zero or Shut Down OVP Output Over Voltage Yes Cooling Cooling Method Convect...

Отзывы: