I. Trouble Shooting

PROBLEM

INDICATIONS

POSSIBLE CAUSES

SUGGESTED SOLUTION

Charger does not
work 

Indicator lights not
on 

No AC power

AC input socket fuse blown 

Check AC connections

Replace with correct AC fuse

No DC output 

Charger - On LED is
not on, Float and
Fault LEDs are  on.

Output short circuit 

Over temperature protection triggered 

Severe over loading charger

Reverse polarity connection

Check DC connections between charger
and battery

Check air intake vent at bottom of charger
is blocked or not. Check charger ambient
ventilation .

Check battery AH capacity within
recommended range

Check for correct polarity, replace car
blade fuse (7)

Battery does not get
full charge

All indicator LED
work normally and
sequentially 

Bad battery connection 

Battery type select switch in wrong setting

Battery capacity too large

Ambient temperature too low 

Battery has damaged cell or battery is too
old 

Check for loose contact

Recheck battery type and change to
correct battery selection

Make sure charger rating matches battery
capacity see table

 

(B2)

Move battery to a room temperature
location, or get an optional temperature
sensor 

Replace battery

Long charging
time , float light
does not come on
even after 20 hours
charging time.

Absorption light
remains on all the
time 

Wrong battery type

Total battery capacity is too high for dual
charging 

Battery temperature too high 

Battery is defective

A load is connected to battery and charger
is not in power supply mode.

Check charged battery label and change
battery type selection to correct setting.

Check battery capacity or charge battery
separately

Use temperature sensor (optional
accessory)

Replace  battery 

Change charger Selector Switch (2) to
Power Supply Mode. 

Bulk LED is on all
the time 

Bulk light remains
on all the time when
Charger is in Power
Supply Mode, LED
(2) is on red.

The connected load is too large, using
most of the current from the charger.

Reduce the load to about 50% of the
charger's rating current or take away the
load and set Charger to Battery Charger
Mode to fully charge the battery

Bulk light remains
on all the time when
Charger is in Battery
Charger mode LED
(2) is on green.

Wrong battery type selection

Battery is excessively depleted and the
soft charging is triggered  

Battery temperature too high

Check battery label and change battery
type selection to correct setting.

Recharge the battery after a day, if bulk
light remains after several hours, the
battery is most likely damaged and cannot
accept charge. Replace battery.

Use optional accessory temperature
sensor

Содержание BC-1210

Страница 1: ...attery Wear protective goggles and turn your face away when connecting or disconnecting the battery Never place the charger on top of a battery Never smoke use an open flame or create sparks near battery or charger during normal charging operation as batteries may give out explosive gas Do not charge batteries in an enclosure box in due to possible explosion of entrapped explosive gas Disconnect t...

Страница 2: ...election Slide Switch to set Charger to 3 Stage Charger or Power Supply Mode See Section G 3 Battery Type Selection Slide Switch to set charger for GEL Wet and Calcium Calcium type battery 4 Float Voltage Selection Slide Switch to set Float Charge voltage to 13 2 13 5V 13 8V 5 Charge Status LED Display Charger ON LED Green 3 Stage Charger Mode Red Power Supply Mode BULK LED Red Bulk Charging with ...

Страница 3: ...tery Charger Installation and Connection Observe the warnings safety precautions before connecting the charger Check battery condition fill up cells for wet battery clean battery posts Secure the battery charger in a well ventilated place make sure the mounting surface is flat The air intake is at the bottom and air outlet at the back Make sure both intake and outlet are not blocked Never place ch...

Страница 4: ...of same chemical make up and type to avoid over and under charging because only one setting of charging profile for both Two batteries are charged simultaneously and the battery with the lowest level gets most share of the current in the Bulk charge stage until it is up to the same voltage level of the second battery battery with higher initial level Both batteries will go to the Absorption and th...

Страница 5: ... is used to optimise charging over wide ambient temperature range Fix the temperature sensor optional accessory in a position on the battery which is not affected by other cooling or heating source Plug in the temperature sensor then switch on the charger to activate the temperature control function never plug in the sensor during charging Fig 4 ...

Страница 6: ...light does not come on even after 20 hours charging time Absorption light remains on all the time Wrong battery type Total battery capacity is too high for dual charging Battery temperature too high Battery is defective A load is connected to battery and charger is not in power supply mode Check charged battery label and change battery type selection to correct setting Check battery capacity or ch...

Страница 7: ... Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically After Fault Condition is Removed Reverse Polarity Car Blade Fuse Over Temperature Protection Type Automatically de rate Charge Current Until Zero or Shut Down OVP Output Over Voltage Yes Cooling Cooling Method Convect...