background image

- FCC COMPLIANCE - 

 

This device complies with part 15 of the FCC Rules. Operation is subject 

to the following two conditions:  (1) This device may not cause harmful 

interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation. If the device 

is not installed and used in accordance with the instructions, it may 

cause harmful interference to radio communications and void the user's 

authority to guarantee the equipment.

 

 

Note: 

This equipment has been tested and found to comply with the 

limits for a Class B digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against 

harmful interference in a residential installation. This equipment 

generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If 

this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and 

on, the user is encouraged to try to correct the interference by one or 

more of the following measures:  

 

 

Reorient or relocate the receiving antenna.  

 

Increase the separation between the equipment and receiver.  

 

Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected.  

 

Consult the dealer or an experienced radio/TV technician for help

.

  

 

Modifications not expressly approved by the manufacturer could void the 

user's authority to operate the equipment under FCC rules. 

 

 

 

 

The CE logo indicates that this product has been tested and shown to conform 

with all applicable European Conformity directives. 
 

 
 

 
 
 
 
 
 

Содержание TRI PARALLEL MIXER

Страница 1: ...n series one after another These are a few examples of the multiple ways to incorporate the Tri Parallel Mixer into your setup USING THE TRI PARALLEL MIXER Plug the 9VDC adapter into the jack on the t...

Страница 2: ...cts loops using the SEND 2 3 and RTN 2 3 jacks Below is the signal path in this configuration Use the CH 1 2 3 footswitches to activate their respective effects loops Double tap any of these footswitc...

Страница 3: ...s each with a SEND and RTN Return jack a SEND and RETURN level control an EQ control a PHASE switch and a footswitch SEND 1 2 3 Jack This jack outputs the signal inputted to the Tri Parallel Mixer via...

Страница 4: ...are other functions these switches can perform which will be discussed later CH 1 2 3 LED This LED lights to indicate which channels are active There are other scenarios where these LEDs may be blinki...

Страница 5: ...after switching the channel off RETURN MUTING In this mode when a channel is inactive only the RETURN SWITCH is opened The SEND SWITCH is always closed and signal will always come out of the SEND 1 2...

Страница 6: ...and the current Muting Mode and AND XOR Mode To easily reset everything to the default settings perform a factory reset by following these steps 1 Unplug the 9V power from the Tri Parallel Mixer 2 Hol...

Страница 7: ...er Machine and combine them in parallel to create a mix of mellotron organ synthesizer and guitar tone In the example above mixing two very different overdrives on bass in parallel can result in a ver...

Страница 8: ...ONFIGURATIONS Over the next couple of pages some other possible configurations and applications of the Tri Parallel Mixer will be shown to help illustrate multiple ways you can use the unit Figure 1 F...

Страница 9: ...ri Parallel Mixer as an instrument switcher Plug each instrument into a channel s RTN jack then set the Tri Parallel Mixer to XOR switching mode and click a channel to select that instrument Use the R...

Страница 10: ...ed below Customers outside the regions listed below please contact EHX Customer Service for information on warranty repairs at info ehx com or 1 718 937 8300 USA and Canadian customers please obtain a...

Страница 11: ...energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a part...

Страница 12: ......

Отзывы: