ElectrIQ SILENT16 Скачать руководство пользователя страница 8

Page 8 of 14 

OPERATION 

This portable air conditioner boasts 3 modes: Cooling, Dehumidifying and Fan. The fan has two speeds: 
high and low. Temperature range  settings  are:  16-31

Ԩ

. The  unit  will  also display  operating function, 

temperature, fault diagnostics and protective functions on the display. 

 

 

 

 

 

 

 

 

 

POWER BUTTON: 

Press to turn the machine in and off. In the case of power on.

 

 

MODE BUTTON: 

Press to change between cooling, fan and dehumidifier modes. 

COOLING MODE: Cold air will be expelled through the front of the unit and hot air will be expelled 
through the vent hose. 
DEHUMIDIFIER MODE:

 The unit should be set up without a vent hose, moisture is extracted from 

the air that passes through the unit. Continuous drainage should be set up for the moisture collected 
(Drainage pipe not included). 
FAN MODE: No cooling effect, circulates air within the room, vent pipe not required. 

 

UP AND DOWN BUTTONS

: These can be used to set the desired temperature between  16 – 31

Ԩ

Following pressing the TIMER button, they are also used to set the timer length.  Press both buttons at 
the same time to change the display between 

Ԩ

 and 

Ԭ

 

FAN SPEED BUTTON: 

IN COOLING AND FAN MODE: Press to change between high, medium and low fan speeds. 
IN DEHUMIDIFY MODE: The fan will default to low speed and cannot be adjusted. 
 

TIMER BUTTON

:    Timer functions cannot be combined or repeated.   

 

POWER ON TIMER: 
With the appliance turned off, press the “TIMER” button to setup the power-on time. Press the UP 
and DOWN buttons to adjust the duration of the timer (from 1 to 24 hours). Timer indicator turns 
on. The unit will start after selected number of hours. 

 

POWER OFF TIMER: 
With the appliance running with the desired settings, press the “TIMER” button to setup the power

-

off timer. Press the UP and DOWN buttons to adjust the duration of the timer (from 1 to 24 hours). 
The timer indicator will illuminate. The unit will stop after selected number of hours. 

 

1:Swing Button    2:Timer Button    3:Fan Speed Button     4:Up button      5:Display
6:Down Button    7:mode Button     8:Sleep Button             9:Power Button

SLEEP BUTTON:

Press to turn on the sleep mode

While the sleep mode is activated in cooling mode, after one hour the desired temperature will be increased 
by 1ºC, after another hour the desired temperature will increase by another 1ºC and remain at that level. 
This means the unit will spend less time with the compressor running, and so run quieter.
Press the MODE button until the sleep mode indicator is illuminated, the fan speed is set to low.
Sleep mode cannot be used in dehumidifying and fan mode.
If the internal tank becomes full, the machine will turn off and sleep mode will be cancelled.

Содержание SILENT16

Страница 1: ...NDITIONER Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co uk for our enti...

Страница 2: ...TENTS SAFETY INSTRUCTIONS 3 OPERATION 8 REMOTE CONTROL 8 EMPTYING THE INTERNAL WATER TANK 10 MANUAL DRAINAGE 10 MAINTENANCE 11 CLEANING 11 END OF SEASON MAINTENANCE 11 TROUBLESHOOTING 12 APPENDIX 13 T...

Страница 3: ...in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a qualified electrician Never operate this appliance if the co...

Страница 4: ...ompromised the refrigerant system Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorized engineer must be...

Страница 5: ...operation mode z On Off timer function allows you to choose when the unit operates z Compressor protection technology PARTS LIST Extendable Exhaust Hose Slide Bar Control panel Top cover Front housing...

Страница 6: ...attached At least 3 full rotations 2 Attach the connector on the opposite end of the pipe to the exhaust outlet on the rear of the appliance by putting it into position and twisting to lock in place 3...

Страница 7: ...room while efficiently cooling it Your air conditioner should be used without the vent pipe in dehumidifier mode When using dehumidifier mode ensure that an external water tank is used monitored and r...

Страница 8: ...FY MODE The fan will default to low speed and cannot be adjusted TIMER BUTTON Timer functions cannot be combined or repeated POWER ON TIMER With the appliance turned off press the TIMER button to setu...

Страница 9: ...the sleep mode The unit will work with energy saving logic and the lowest fan speed MULTI PROTECTIVE FUNCTIONS OVERFLOW PROTECTION FUNCTION When the water in the internal water tank exceeds the warni...

Страница 10: ...k Put the rubber stopper back into place CONTINUOUS DRAINAGE Unscrew the drain plug cap and remove the rubber stopper Connect a water pipe to the water outlet Not Supplied You can plumb this pipe into...

Страница 11: ...al detergent about 40 104 and dry it in the shade after rinsing clean CLEAN THE LOWER FILTER SCREEN FRAME Hold the handle of the air inlet filter screen frame and pull it outward gently to remove it P...

Страница 12: ...is user manual and hose is not bent Loud Noise The air conditioning is not placed on a flat surface Put the air conditioning on a flat and hard place to reduce noise Compressor does not work Overheat...

Страница 13: ...ase be considerate when depositing your equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA MODEL SILENT1 V2 Capacity Cooling kWh 1 00...

Страница 14: ...omplete the online form 0871 620 1057 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to se...

Отзывы: