R290 refrigerant gas complies with European

environmental directives.

R290  has  a  low  GWP  (Global  Warming

Potential) of 3.

The  air  conditioner  contains  about  2

0  g  of

R290 refrigerant gas.

Do  not use or store  in an unventilated  space

with  an  area smaller  than  1

m

2

 per unit. The

room must be such as to prevent stagnation of

possible leaks of refrigerant gas as there could

be a danger of fire or explosion hazard should

the refrigerant come into contact with electric

heaters, stoves or other sources of ignition. 

If the appliance is installed, used or stored in an unventilated room, the room
must be such as to prevent stagnation of possible leaks of refrigerant gas as
there  could  be  a  danger  of  fire  or  explosion  should  the  refrigerant  come  into
contact with electric heaters, stoves or other sources of ignition.

Refrigerant gas may be odourless.

Do  not  use  the  product  and  contact  the  retailer  for  advice,  if  damage  has
occurred to the unit which may have compromised the refrigerant system.

Any repairs or maintenance must only be carried out on the unit by a suitably
qualified engineer. Before opening and servicing the unit the authorized engineer
must be in possession of a copy of the manufacturer’s service manual and must
follow  the  safety  information  contained  within  it  to  ensure  all  hazards  are
minimized.

The refrigerant system should not be perforated or punctured.

Energy Saving and Unit Safety Protection Tips 

Do not cover or restrict the airflow from the outlet or inlet grills.

For maximum performance the minimum distance from a wall or objects
should be 50cm.

Keep the filters clean. Under normal conditions, filters should only need
cleaning once every three weeks (approximately). Since the filters remove
airborne particles, more frequent cleaning maybe necessary, depending on
the air quality.

For the initial start up set the fan speed to maximum and the thermostat to 4-
5 degrees lower than the current temperature. After, set the fan switch to low
and set the thermostat to your desired setting.

To protect the unit we recommend not using the cooling function when the
ambient temperature is higher than 35

o

C.

Содержание SILENT16

Страница 1: ...NDITIONER Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co uk for our enti...

Страница 2: ...TENTS SAFETY INSTRUCTIONS 3 OPERATION 8 REMOTE CONTROL 8 EMPTYING THE INTERNAL WATER TANK 10 MANUAL DRAINAGE 10 MAINTENANCE 11 CLEANING 11 END OF SEASON MAINTENANCE 11 TROUBLESHOOTING 12 APPENDIX 13 T...

Страница 3: ...in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a qualified electrician Never operate this appliance if the co...

Страница 4: ...ompromised the refrigerant system Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorized engineer must be...

Страница 5: ...operation mode z On Off timer function allows you to choose when the unit operates z Compressor protection technology PARTS LIST Extendable Exhaust Hose Slide Bar Control panel Top cover Front housing...

Страница 6: ...attached At least 3 full rotations 2 Attach the connector on the opposite end of the pipe to the exhaust outlet on the rear of the appliance by putting it into position and twisting to lock in place 3...

Страница 7: ...room while efficiently cooling it Your air conditioner should be used without the vent pipe in dehumidifier mode When using dehumidifier mode ensure that an external water tank is used monitored and r...

Страница 8: ...FY MODE The fan will default to low speed and cannot be adjusted TIMER BUTTON Timer functions cannot be combined or repeated POWER ON TIMER With the appliance turned off press the TIMER button to setu...

Страница 9: ...the sleep mode The unit will work with energy saving logic and the lowest fan speed MULTI PROTECTIVE FUNCTIONS OVERFLOW PROTECTION FUNCTION When the water in the internal water tank exceeds the warni...

Страница 10: ...k Put the rubber stopper back into place CONTINUOUS DRAINAGE Unscrew the drain plug cap and remove the rubber stopper Connect a water pipe to the water outlet Not Supplied You can plumb this pipe into...

Страница 11: ...al detergent about 40 104 and dry it in the shade after rinsing clean CLEAN THE LOWER FILTER SCREEN FRAME Hold the handle of the air inlet filter screen frame and pull it outward gently to remove it P...

Страница 12: ...is user manual and hose is not bent Loud Noise The air conditioning is not placed on a flat surface Put the air conditioning on a flat and hard place to reduce noise Compressor does not work Overheat...

Страница 13: ...ase be considerate when depositing your equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA MODEL SILENT1 V2 Capacity Cooling kWh 1 00...

Страница 14: ...omplete the online form 0871 620 1057 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to se...

Отзывы: