SAFETY INSTRUCTIONS 
 

Important! 

  Carefully read the instructions before operating the unit 

  This appliance is for indoor use only. 

  Rating: This unit must be only connected to a 220-240 V / 

50 Hz earthed outlet. 

  Installation must be in accordance with regulations of the country where the 

unit is used. 

  If you are in any doubt about the suitability of your electrical supply have it 

checked and, if necessary, modified by a qualified electrician. 

  This air conditioner has been tested and is safe to use. However, as with any 

electrical appliance - use it with care. 

  Disconnect the power from the appliance before dismantling, assembling or 

cleaning. 

  Avoid touching any moving parts of the appliance. 

  Never insert fingers, pencils or any other objects though the guard 

  This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities. It is also not intended for 
use by those with a lack of experience and knowledge, unless they have 
been given supervision or instruction concerning the use of the appliance by 
a person responsible for their safety. 

  Do not leave children unsupervised with this appliance. 

  Do not clean the unit by spraying it or immersing it in water. 

  Never connect the unit to an electrical outlet using an extension cord. If an 

outlet is not available, one should be installed by a qualified electrician. 

  Never operate this appliance if the cord or plug is damaged. Ensure the 

power cord is not stretched or exposed to sharp objects/edges. 

  A damaged supply cord should be replaced by the manufacturer or a 

qualified electrician in order to avoid a hazard. 

  Any service other than regular cleaning or filter replacement should be 

performed by an authorised service representative. Failure to comply could 
result in a voided warranty. 

  Do not use the appliance for any other purposes than its intended use. 

 

The air conditioner unit must always be stored and transported upright, 
otherwise irreparable damage may be caused to the compressor; if in 
doubt we suggest waiting at least 24 hours before starting the unit. 

  Avoid restarting the air conditioning unit unless 3 minutes have passed since 

being turned off. This prevents damage to the compressor. 

  Never use the mains plug as a switch to start and turn off the air conditioning 

unit. Use the provided ON/OFF switch located on the control panel. 

  Always place the unit on a dry and stable surface. 

  The appliance should not be installed in laundry or wet rooms. 

  The appliance must be placed in a room without sources of ignition (for example: 

open flames, an operating gas appliance or an operating electric heater). 

 

 

Содержание SILENT16

Страница 1: ...NDITIONER Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co uk for our enti...

Страница 2: ...TENTS SAFETY INSTRUCTIONS 3 OPERATION 8 REMOTE CONTROL 8 EMPTYING THE INTERNAL WATER TANK 10 MANUAL DRAINAGE 10 MAINTENANCE 11 CLEANING 11 END OF SEASON MAINTENANCE 11 TROUBLESHOOTING 12 APPENDIX 13 T...

Страница 3: ...in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a qualified electrician Never operate this appliance if the co...

Страница 4: ...ompromised the refrigerant system Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorized engineer must be...

Страница 5: ...operation mode z On Off timer function allows you to choose when the unit operates z Compressor protection technology PARTS LIST Extendable Exhaust Hose Slide Bar Control panel Top cover Front housing...

Страница 6: ...attached At least 3 full rotations 2 Attach the connector on the opposite end of the pipe to the exhaust outlet on the rear of the appliance by putting it into position and twisting to lock in place 3...

Страница 7: ...room while efficiently cooling it Your air conditioner should be used without the vent pipe in dehumidifier mode When using dehumidifier mode ensure that an external water tank is used monitored and r...

Страница 8: ...FY MODE The fan will default to low speed and cannot be adjusted TIMER BUTTON Timer functions cannot be combined or repeated POWER ON TIMER With the appliance turned off press the TIMER button to setu...

Страница 9: ...the sleep mode The unit will work with energy saving logic and the lowest fan speed MULTI PROTECTIVE FUNCTIONS OVERFLOW PROTECTION FUNCTION When the water in the internal water tank exceeds the warni...

Страница 10: ...k Put the rubber stopper back into place CONTINUOUS DRAINAGE Unscrew the drain plug cap and remove the rubber stopper Connect a water pipe to the water outlet Not Supplied You can plumb this pipe into...

Страница 11: ...al detergent about 40 104 and dry it in the shade after rinsing clean CLEAN THE LOWER FILTER SCREEN FRAME Hold the handle of the air inlet filter screen frame and pull it outward gently to remove it P...

Страница 12: ...is user manual and hose is not bent Loud Noise The air conditioning is not placed on a flat surface Put the air conditioning on a flat and hard place to reduce noise Compressor does not work Overheat...

Страница 13: ...ase be considerate when depositing your equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA MODEL SILENT1 V2 Capacity Cooling kWh 1 00...

Страница 14: ...omplete the online form 0871 620 1057 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to se...