ElectrIQ ECD70 Скачать руководство пользователя страница 11

11 

 

CARE AND MAINTENANCE 

Always shut off the unit and unplug it from the mains before cleaning or performing any maintenance. 
When it is not in use for long periods, it is advisable to remove the plug from the power socket. Do not use 
chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit. 

CLEAN THE AIR INLET 

The Air-inlet may gather dust easily, please clean it often with a soft, damp cloth. If the filter is covered by 
dust, the airflow and the performance of the unit will be affected, it may even cause damage to the unit. 
We recommend that you regularly clean the filters. The dehumidifier must be disconnected from the 
socket before maintenance and the filters must be allowed to fully dry before re use. 
 

1.

 

Remove the filters from the unit, and tap the dust away. 

2.

 

cleaner or soft-brush. 

3.

 

If dirt and grease is accumulated wash the mesh filter in hot soapy water. 

4.

 

Replace the filters in position as shown in the diagram. 

5.

 

Never use the unit without the antibacterial mesh dust filter. 

 

CLEAN THE GRILLE AND CASE 

Use water and a mild detergent to clean the washable mesh filters. Do not use bleach or abrasives. Do not 
splash water directly onto the main unit. Doing so may cause an electrical shock and can lead to the 
insulation to deteriorate, or cause the unit to rust. The air intake and outlet grilles get soiled easily, so use 
a vacuum attachment or soft brush to clean. Wipe the dehumidifier body with 
a soft damp cloth or kitchen towel. 

 

END OF SEASON MAINTENANCE

 

 

1.

 

Clean the unit and the filter as per cleaning procedure above. 

2.

 

Cover the unit and keep it in a dry place. 

 

CAUTION: 

 

When not in use, the user should switch the unit off by pressing the Power button so that the indicator 
LED is turned off, before unplugging it from the mains. 

 

Always follow the safety instructions outlined at the beginning of the user manual. 

 

Disconnect the dehumidifier from the mains if the unit is not in use. 

 

To prolong the life of the dehumidifier, do not use for long periods of time without disconnecting the 
unit from the power supply. 

 

 

Содержание ECD70

Страница 1: ...ER ECD70 70 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier Please keep it safe for future reference Visit our page www electriQ c...

Страница 2: ...TS 5 FEATURES 6 PRODUCT OVERVIEW 6 POSITIONING THE DEHUMIDIFIER 7 ASSEMBLY 8 OPERATION 9 CONTINUOUS DRAINAGE 10 CARE AND MAINTENANCE 11 TROUBLESHOOTING 12 FREQUENTLY ASKED QUESTIONS 13 TECHNICAL SPECI...

Страница 3: ...it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate t...

Страница 4: ...ensure all hazards are minimized The refrigerant system should not be perforated or punctured Do not place the unit next to heat sources e g electrical fires fireplaces etc Avoid mishandling the dehu...

Страница 5: ...AFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER PARTS Bolts For Axel x 4 Bolts For Handle x 4 6m Flexible Water Pipe x 1 Pre attached to the unit Nuts For Wheels x 2 Washers For Wheels x 2 W...

Страница 6: ...tive humidity can be adjusted in increments of 5 between 40 and 95 ensuring your room is not dried too much and power is not wasted FEATURES Your dehumidifier belongs to the electriQ dehumidifier rang...

Страница 7: ...r this reason the dehumidifier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the home A warm hallway or landing is an excellent posit...

Страница 8: ...e plugging in ATTACHING THE WHEELS 1 Attach the Axel to the base of the appliance using the 4 bolts provided 2 Fix the wheels onto each end of the axel using the supplied washers and nuts ensuring tha...

Страница 9: ...ed to adjust the timer duration following pressing the TIMER button Press the timer button to activate the timer Use the UP and DOWN buttons to adjust the timer duration 00 24hr The timer can be used...

Страница 10: ...the previously operating settings DEFROSTING MODE DESCRIPTION Automatic defrosting Sensor at normal state This mode is entered when the compressor runs constantly for 30 min and the coil temperature i...

Страница 11: ...n position as shown in the diagram 5 Never use the unit without the antibacterial mesh dust filter CLEAN THE GRILLE AND CASE Use water and a mild detergent to clean the washable mesh filters Do not us...

Страница 12: ...er manual Unit is noisy during operation Is the unit on an uneven surface Please place on flat horizontal surface Is filter clogged Please service the filters regularly as per user manual Unit leaking...

Страница 13: ...A Drainage Pipe Internal Diameter 4mm Maximum uplift of condensate 5m Product Dimensions mm 460x870x545mm Weight Kgs 42 Refrigerant R290 280g Minimum room area M2 14 Global Warming Potential 3 Operati...

Страница 14: ...old cycle there should be cold air coming out of the unit During the hot cycle hot dry air should be coming out of the outlet grill ENVIRONMENTAL PROTECTION Disposal Do not dispose this product as uns...

Отзывы: