8
Humidity Level & Timer 2 digit display
The led indicator performs the following functions: 1. When the unit is plugged in, it will indicate
the room humidity level 2. When the humidity level is selected, it will indicate the set humidity
3. When the start / stop timer is programmed will show the set timer
Notes:
When humidity level is outside the normal operational parameters will show
LO/HI. If ambient humidity is lower than 35%, it will show “LO”
If ambient humidity
is higher than 95%, it will show “HI”. Also the display will show the error codes.
Quick Reference Guide
Power Key
Press
to turn the dehumidifier on and off.
Timer
: select timer settings key
to adjust the timer (1-24 hrs, start/ stopping timer). In
power on mode the set number will represent the number of hours the unit will run for before
turning off. This will remain unaffected if unit goes in to defrost mode or the tank is emptied then
reinserted. In standby mode the set number represents the period in hours after which the unit
will start. To cancel start / stop mode press the timer key again until is set to
0
.
Press
Up
or
Down
Settings Key when the unit is displaying the current relative
humidity to select the desired humidity level. Humidity level can be set within a range of 30% RH
(Relative Humidity) to 90% RH in 5% increments.
When the humidity is lower by 2% than the set humidity the unit will stop the compressor and
work for 3 minutes in fan only. When humidity is higher by 2% than selected humidity the
compressor will start working after a 3 minutes delay. There is humidity measurement tolerance.
Laundry Mode:
For CD20L press
to automatically set the dehumidifier in laundry mode.
Fan is set to
high on laundry mode
For CD10L set the humidity to
CO
to operate continuously with maximum water extraction until
the tank is full. Alternatively you can set the humidity level to 35%-40%RH. <40% is very dry and
the unit will work until water tank is full as 35%RH is hardly achievable in UK domestic
environment. Do not place clothes directly over any of the dehumidifier vents. Make sure that
there is nothing blocking the hot air exhaust air flow and for best results place the laundry within
1.5 meters of the dehumidifier.
Note
that if permanent drainage pipe is fitted the unit will not stop operation. Humidity set to
achieve room humidity of around 35% is good for quick drying boost on initial run or emergencies,
laundry mode. Not recommended for long normal operation in domestic/ office environment.
For allowing more moisture in the air, press the humidity control key and set to a higher percent
value (e.g. 60-70%).
Humidity set to 50-55% RH; recommended setting, great for domestic operation and dry storage
Humidity set to 60% RH; great for personal comfort and applications where 50% RH is considered
too dry
Humidity set to 70% RH; ideal for unoccupied properties or where economical run is needed
without the need to go drier than 70% RH