![ElectrIQ CD10L Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/electriq/cd10l/cd10l_user-manual_2379384010.webp)
9
Other features and Indicators
Tank Full Light
Red light will be on and the unit will beep when the tank is ready to be emptied, or when the
tank is removed or not replaced in the proper position. The water level control switch shuts off
the dehumidifier when the tank is full, or when the tank is removed or not replaced in the proper
position. Empty and replace to resume operation.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in
to defrost mode
When the unit is running in a room with temperature between 5
o
C and 12
o
C, it enters the defrost
mode about once every 30 minutes.
When the unit is running in a room with temperature between 12⁰C and 20⁰C, it enters the
defrost mode about once every 45 minutes.
Normal operation will resume after defrost mode.
Humidistat control and fan/ compressor operation
When the selected humidity is 2% lower than the user selected humidistat setting; the
dehumidifier’s compressor will be shut off automatically but the fan will still move to ensure air is
not stale in the room. The unit will use only a minimal amount of energy in fan mode.
When the humidity is equal or higher than user selected humidity the compressor will restart
once the 3 minutes delay compressor protection expires.
Power
After the unit has stopped, it is not recommended to resume operation for at least 10 minutes.
This is to protect the compressor. Operation can resume after this period lapses. When the unit is
restarted there is a 3 minutes delay before compressor will start.
Lightweight Portable Design
The dehumidifier is built to be compact and lightweight.
Your CD10L/CD20L dehumidifier is an advanced micro-CPU controlled device able of
self-diagnostics. The LED display may also show the error and protections codes.