1 0 | H O M E S TAT I O N L E V E L 2 C H A R G E R
3
Installation with Hardwiring
These installation instructions are intended for certified electricians. Only
qualified, certified electricians should hardwire the charger. In addition
to the charger installation instructions, follow all federal, provincial, and local
laws, regulations, ordinances, codes, and safety standards.
This product must be properly grounded —either to a grounded, metal,
permanent wiring system or an equipment-grounding conductor run with
the supply power circuit conductors and connected to the grounding
terminal on the product.
C AU TI O N :
To reduce the risk of fire, connect only to a circuit provided with 50
amperes maximum branch circuit overcurrent protection in accordance with
the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code,
Part 1, C22.1.
1
REMOVE THE COSMETIC AND MIDDLE COVERS
1. Remove the screw located at the bottom of cosmetic cover by using the
T20 Torx bit.
2. Tilt the cosmetic cover upward and separate it from the middle cover.
3. Remove the screws using the T20 Torx bit.
4. Place the middle cover on the body of the charger by hanging the two hooks
on the back of the middle cover to the ledges at the bottom of the body.
5. Once the cover has been removed, open the cable management clip on
the right-hand side of the enclosure to release the LED cable attached to the
cover. This will allow the cover to be hung on the bottom of the enclosure.
2
REMOVE THE PLUG CABLE
1. Remove the plug cable by loosening the 3 center screws (shown as L1, L2, and
PE) in the terminal block. Do not loosen the screws securing the terminal block
to the body.
2. This product has two means of strain relief: a metal bracket on the interior
of the body and a black nut on the outside of the body.
3. Loosen the left strain relief nut on the outside of the body.
4. Remove the left strain relief strap from the inside of the body.
5. Pull the cable down through the cable gland and remove the strain
relief nut from the plug cable.
3
FLIP THE COSMETIC COVER UPWARD TO SEPARATE IT FROM THE BODY
1. Insert the new cable through the cable gland nut, then into the body
of the charger.
N OT E:
The conductor size may be no less than 6 AWG.
During installation, be sure to use proper personal protective equipment
and do not touch wiring terminals with your fingers.
N OT E:
The circuit breaker must be rated for 125% of the chosen