Electrify America EA2R040JPA10-00 Скачать руководство пользователя страница 5

7)

 

The ambient operating temperature range for this device is -22°F (-30°C) to 122°F (50°C). 
Do not operate the charger outside this operating range. 

8)

 

Electrify America is not responsible for physical injury, damage to property or equipment 
caused by the installation, usage, repair, or maintenance of this product. 

9)

 

These operating instructions describe the usage of the charger in most commonly used 
installation and mounting scenarios. If situations arise in which it is not possible to 
perform an operation following the procedures provided in this document, contact 
Electrify America. Electrify America is not responsible for any damages that may occur 
resulting from custom installations or operations that are not described in this document. 

10)

 

Personal Protection Equipment: Use of proper personal protection equipment, including, but not 
limited to, eye protection, shock protection, gloves, and other appropriate protection, is 
recommended when installing or servicing any electrical equipment. To reduce the risk of fire, only 
connect this equipment to a maximum 50 amperes overcurrent protection device in accordance 
with the National Electrical Code, ANSI/NFPA.

 

 

11)

 

Do not use this equipment in an area with hazardous or flammable materials or vapors. 

 

12)

 

Arcing Component in Contactor: The charger includes contactors that, when opened or closed, will 
cause a short duration arc. The contactor is enclosed in an appropriate electrical enclosure, but 
caution is required if this arc occurs in the presence of flammable vapors as the vapors could ignite, 
creating an explosion. Store hazardous and flammable vapors and materials away from all electrical 
equipment. If hazardous or flammable sources are present, allow sufficient time for ventilation 
before operating the charger. 

 

13)

 

Do not open the charger at any time during installation or operation! Only trained personnel should 
open the charger. 

 

14)

 

Handling live components incorrectly may cause grievous injuries or death. 

 

15)

 

If the electricity service to the charger is damaged, immediately shut down the power to the 
charger by switching off the circuit breaker and contact a licensed electrician. 

 

16)

 

Turn off circuit before remounting or replacing the charger. 

 

17)

 

To reduce the risk of fire, connect only to a circuit provided with the proper maximum branch 
circuit overcurrent protection in accordance with the National Electrical Code and local laws, 
regulations, codes, and standards. 

 

18)

 

Ensure that all components are dry throughout the installation. 

 

19)

 

Product subject to modification without prior notice. This document might not contain the latest 
changes to the product’s specifications or processes described herein. For the most up-to-date 
information, please visit 

electrifyhome.com 

 

 

 

6 ) EMC Compliance Statement: FCC Part 15 Subpart B, Class B

 

 

 

FCC ID: 2AX8SEA2R040JPA1000 

1)

 

RF Exposure warning   

This equipment must be installed and operated in accordance with provided instructions and the 
antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 
cm from all persons and must not be co-located or operating in conjunction with any other antenna 
or transmitter. End-users and installers must be provide with antenna installation instructions and 
transmitter operating conditions for satisfying RF exposure compliance.  

2)

 

FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT  

Содержание EA2R040JPA10-00

Страница 1: ...HomeStation Level 2 Charger INSTALLATION AND OPERATION MANUAL Version 1 0 0 Issue Date December 11 2020...

Страница 2: ...ELECTRIFYHOME COM Customer Support 833 532 2778...

Страница 3: ...ERVIEW o Included Component List o Recommended Tools INSTALLATION INSTRUCTIONS o Before Installing o Installation Steps o Installation with Hardwiring OPERATING INSTRUCTIONS CHARGER STATUS o Status In...

Страница 4: ...rging current control via the pilot signal IEC 61851 1 Do not use the charger to charger or supply other devices Follow all federal provincial and local laws regulations ordinances and safety standard...

Страница 5: ...nd flammable vapors and materials away from all electrical equipment If hazardous or flammable sources are present allow sufficient time for ventilation before operating the charger 13 Do not open the...

Страница 6: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Страница 7: ...Product Overview...

Страница 8: ...S FOR PLUG IN INSTALLATION 1 Level 2 Pencil 3 Electric Drill 4 Philips head Screwdriver 2 TOOLS FOR HARDWIRED INSTALLATION 1 Level 2 Pencil 3 Electric Drill 4 Phillips Head Screwdriver 5 Diagonal Cutt...

Страница 9: ...lectrician to determine the amperage setting that best fit your home s electrical capacity This may determine which type of installation you will need and the best location for the charger Configurati...

Страница 10: ...nstall the charger make sure that when your electric vehicle is parked the charge cable can easily connect to the vehicle Keep in mind where the vehicle s charging port is located it varies from vehic...

Страница 11: ...ded with the product shows the proper location to drill pilot holes for the mounting bracket screws 2 Using a level place the mounting template in the location where you would like to mount the charge...

Страница 12: ...minal on the product CAUTION To reduce the risk of fire connect only to a circuit provided with 50 amperes maximum branch circuit overcurrent protection in accordance with the National Electrical Code...

Страница 13: ...l block ensuring the wires are located properly 1 Tighten terminal block screws to 33 40 in lb 3 73 4 5 N M of torque 2 Reinstall and tighten the strain relief strap ensuring the wires are not straine...

Страница 14: ...your phone s Wi Fi is turned on It is not required to be connected to a network 3 Follow the instructions in the App to connect to your charger and configure your amperage setting 4 Wi Fi Setup Plug i...

Страница 15: ...off 1 second on 5 seconds off 3 flashes These follow the same patterns as above Understanding Status Indicator Patterns LED COLOR INDICATOR DESCRIPTION No color Power off Blue green alternating and f...

Страница 16: ...Red solid Self test error or general error Disconnect the charger from power and reconnect to power after 10 seconds to power cycle the charger...

Страница 17: ...778 Indicator starts to flash red while charging Charger has detected an error Charger has encountered a fault Wait until the temporary error is resolved and the charger returns to normal condition ty...

Страница 18: ...l ISO 15118 User Interface HMI LED Light Ring Wireless WLAN with 2 4GHz b g n with WPA2 Communication Protocol OCPP 1 6 JSON Compliant AC Fault Monitor GFCI Integrated 20mA CCID for AC Short Circuit O...

Страница 19: ...cable is frayed has broken insulation or any other signs of damage Do not use this product if the enclosure or the electric vehicle connector is broken cracked open or shows any other indication of da...