3.
Installation
(cont.)
Control cabling – RF models
All Radio Frequency radiators come complete with a pre-wired TEI-5 Receiver which is
controlled by either the TEI-6 or TEI-7 RF Programmers.
11.
TEI-6 installations
a
Follow the instructions outlined in section 8 for single radiator installations.
b
Locate the TEI-6 programmer on a suitable wall in the same room as the radiator.
c
Configure the TEI6 programmer and TEI-5 receiver located on the radiator
according to the instructions included in the TEI-6 packaging.
d
Set the required program times and temperatures.
12.
TEI-8 installations
a
Follow the instructions outlined in section 8 for single radiator installations.
b
Locate the TEI-8 digital room thermostat on a suitable wall in the same room as
the radiator.
c
Configure the TEI-8 digital room thermostat and TEI-5 receiver located on the
radiator according to the instructions included in the TEI-8 packaging.
d
Set the required temperature by adjusting the +/- buttons.
CAUTION - After completion of works all electrical connections should be
tested for tightness. Additionally an electrical safety check should be carried
out ie: short circuit, earth continuity, resistance to earth and polarity check
and all the relevant test certificates produced.
Installing castors and feet
13.
All radiators are supplied with wall mounting brackets, however with the exception of
the Towel Rail they can also be mounted on feet or castors. Consult the leaflet which
comes with them for fixing instructions. If not fixed to a wall, the official feet or castors
must be used.