background image

3

Functions of the video outdoor panels

4

Recommended cables. Installation.

     

The outdoor panel is mounted on the wall at a height of 1.60 m from the upper edge of the panel (see page 

1

).

     

Depending on the maximum distance between the outdoor panel and the last terminal in the installation, the recommended 

     

cables are the following:

2

     

Option 1) 4 wires x 0.5 mm  

(type H03VV-F4G 0.5) for

 maximum 75 lm

2

     

Option 2) 4 wires x 0.75 mm  

(type H05VV-F4G 0.75) for

 maximum 150 lm

Build features:

   

Solid mechanical construction, built in embedded technology, with chemically toughened glass.

   

Weatherproof, waterproof and with an operating temperature range between -30º…+ 60º C.

 

  

Electronic anti-condensation system for the video camera screen.

   

Anti-theft sensor that is activated during unauthorized unmounting from the wall.

 

  

Day/night sensor for the command of TOUCH keyboard backlighting and the lighting of the IR LEDs and IR-CUT.

   

TOUCH keyboard with the name of the resident, backlighted during night.

   

1/3 CMOS, 900TVL color video camera and IR LEDs for b/w image during night.

   

Blinking red LED, signaling the presence of potential video monitoring from the panel.

   

In-built RFID reader.  Access by secured RFID tag/card.

   

Allows the connection of a DVR, for extended monitoring and video recording from the panel.

Settings/Programming

  

 Programming and deletion of RFID building access tags/cards.

  

 Programming of new address 2, 3 or 4, for parallel connected panels, in case of buildings with multiple entrances.

   

(maximum 4 outdoor panels for one building).

   

Enabling or disabling of video monitoring signaling (Red LED ON/OFF), through the 

J

P

1

RED LED/0. (

ch.

 4.1-

step

 4)

 

   Enabling or disabling DVR video recording (ON/OFF) through the 

jumper 

JP40: 1-2 (OFF) / 2-3(ON) (

ch

. 4.1)

Extensions

   

Allows the parallel connection of maximum 4 outdoor panels, through a video selection box (VSB).

  

 Allows the connection of an additional video camera directly to the central supply unit (SCU), or of 4 additional 

   

video cameras, through a video selection box (VSB).

 

Connections

to the VPM

outdoor panel

+U
C/D

GND

+U

C/D

GND

UTP cat5e (AWG24)

UTP cat6e (AWG23)

25-30mm

6mm

Vin

Vout

6mm

25-30mm

Connections 

to the SCU

central supply unit

+U
C/D
GND

Vin

+U

C/D

6mm

25-30mm

GND

Vout

6mm

25-30mm

Connections 

to the SCU

central supply unit

Connections 

to the VPM

outdoor panel

EN

2

      
*Important: 

    

 Maintain the same colors for the same connections.

Example: 

+U

 = Red, 

C/D 

= Blue, 

GND

 = Black, 

Vin/Vout

 = Green.

    

For electrical safety reasons, we recommend installing an earthing cable between the panel and the SCU, connected to an

    

earth grounding 

 

(ISO - IEC 60950-1:2005)

 

Option 3) UTP cat5e (AWG24) 

or

 UTP cat6e (AWG23), 

for

 maximum 250 lm

            The wires will be arranged as per the below table:

EN

EN

Содержание VPM.1FR02

Страница 1: ...VIDEO OUTDOOR PANELS 1 5 Families for TL door phone systems User manual 4 wires 1 Fam Video 2 Fam Video 3 Fam Video 5 Fam Video EN ...

Страница 2: ...H x 597 V 800 TVL video 1 Vpp 75 W PAL 70º 25º orientable video camera Case aluminum 4 mm chemicallytoughened glass IR LEDs 850 nm IR CUT for night vision 10m TOUCH keys for call and family name backlighted during night Access RFID card Access RFID card Wall mounting height 160 cm 1 52 kg EN EN Any intervention on the installation must be performed byAUTHORIZED PERSONNEL DO NOT power the product a...

Страница 3: ...itoring and video recording from the panel Settings Programming Programming and deletion of RFID building access tags cards Programming of new address 2 3 or 4 for parallel connected panels in case of buildings with multiple entrances maximum 4 outdoor panels for one building Enabling or disabling of video monitoring signaling Red LED ON OFF through the JP1 RED LED 0 ch 4 1 step 4 Enabling or disa...

Страница 4: ...o 25 o 25 o 30 o 30 EN 3 5 cm 20 cm 20 cm 1 5 cm Mount back the family name module Signaling of video monitoring JP1 on RED LED position No video monitoring signaling JP1 on 0 position Mounting on the wall Surface Unmount the module and add name labels EN STEP 2 STEP 3 STEP 4 STEP 5 JP1 RED LED 0 o 70 0 JP2 DVR DVR JP 2 0 Video camera angle adjustment The video camera will be oriented towards the ...

Страница 5: ...ns in the panel Torx Mounting the outdoor panel on the wall Surface Important For both types of mounting the Torx screws for fastening the outdoor panels on the wall will be very well tightened to prevent the anti theft alarm sensor from setting off U C D GND Vout U C D GND Vout 4 2 EN STEP 1 STEP 1 1 EN 4 ...

Страница 6: ...GNG 2 GNG 1 DBL 1 DBL 2 Doorbell GONG Fam 1 address 1 U C D GND Vin Note2 Any type of TL terminal can be mounted indoors For Fam 1 the terminal has address 1 which is set by the producer The additional terminals mounted in parallel will have the address of the main terminal For Fam 2 the terminal will be programmed with address 2 See Ch 6 of the user manual for TL audio video terminals Note1 For r...

Страница 7: ... Fam 3 Note For residences with 3 families and one entrance entrance 1 the outdoor panel has address 1 which is set by the producer For multiple entrances Entrance 2 Entrance 3 Entrance 4 panels 2 3 and 4 will be programmed according to the procedure in Ch 4 6 Note Any type of TL terminal can be mounted indoors For Fam 1 the terminal has address 1 which is set by the producer The additional termin...

Страница 8: ...ances Entrance 2 Entrance 3 Entrance 4 panels 2 3 and 4 will be programmed according to the procedure in Ch 4 6 VPM address 1 GONG GONG GONG GONG Vcam U GND Vin2 110Va c 50Hz 60Hz 230Va c 50Hz 60Hz U C D GND Vin SCU OUT1 U PROG BAT 110 230V SWC 1 SWC 2 SWC LC 1 LC 2 LCK AUX 1 AUX 2 LA 1 LA 2 LS 1 LS 2 AUX L N 2x6Aa c OUT2 U C D GND Vout U C D GND Vout Doorbell GNG 2 GNG 1 DBL 1 DBL 2 U C D GND Vin...

Страница 9: ... Long press the PROG button at SCU 2 Long touch the Fam 1 keyat the VPM2 panel long beep Short touch the Fam 1 key twice Two short beeps confirmation The VPM3 panel with address 3 Long press the PROG button at SCU 3 Long touch the Fam 1 keyat the VPM3 panel long beep Short touch the Fam 1 key three times Three short beeps confirmation The VPM4 panel with address 4 Long press the PROG button at SCU 4...

Страница 10: ...n the outdoor panel During programming the installation has to be connected to the grid 110V 230Va c and fully operational 1 Go to the place where the SCU central unit of the installation is mounted Long press 3 sec the PROG button on the SCU The Red LED turns on 2 Take the RFID tags cards to the outdoor panels To program them approach every tag card for one second to the RFID area of the outdoor ...

Страница 11: ...e when you perform point 2 of chapter 5 1 it is mandatory to approach both the new access tags cards and the old tags cards to the RFID area of the panel for reprogramming 4 After performing point 3 of chapter 5 1 check if access is granted for all the programmed and reprogrammed RFID access tags cards The Touch Line audio video terminals must be kept away from water lime or any liquid substances ...

Страница 12: ...tion at Building Communications GmbH Certificate no E307311 ISO 9001 2008 ISO 14001 2009 Certificates no 73 100 4856 73 104 4856 by TÜV HESSEN The products are manufactured under Quality and Environment Management System The products are CE certified R The products contain UL compliant printed circuit boards Certificate by R 709 ICPE ELECTRA is a trademark of ELECTRA Group No 008958332 EUIPO Alicante ...

Отзывы: