8
(6)
LUX ADJUSTMENT
The LUX adjustment determines at what brightness
level the connected light will turn on when you set the
sensor to automatic operation.
For instance, turn the LUX knob clockwise to the
MOON position (FIGURE 14) and the light will only
turn on at low illumination (below 20 Lux).
To set the preferred ambient light in higher level to
turn the light on, just slowly turn the LUX knob
counterclockwise to increase the Lux setting. Keep
creating motion during the process. When the light is
on, it means the preferred Lux level is set.
The adjustable Lux range is about 20 - 300 Lux. Set
the Lux setting according to your requirements.
FIGURE 14
OPERATION MODE
If you connect external wall switch to your PAM60,
you can operate automatic and manual override
alternatively.
(1) AUTOMATIC MODE
Turn on the wall switch; when the sensor detects
motion, the light automatically turns on according to
the ambient brightness level set by LUX knob.
(2) MANUAL OVERRIDE MODE
You can override the sensor to keep the light on
regardless of the motion, just to press the wall switch
off and on twice within 4 seconds to enter the mode.
The interval between the first and second operation
must be within 0.5 - 2 seconds.
In Manual Override mode, the light will remain on for
around 4 ~ 6 hours despite no motion; then the light
will turn off and the motion sensor be back to Auto
mode automatically.
Users can also set the motion sensor back to Auto
Operation by pressing off the wall switch for at least
10 seconds and then turn it back on.
TROUBLESHOOTING
Light does not turn on:
Check the correct wiring connection.
Check the connected wall switch in “ON” state.
Check the connected light in good condition.
Check the LUX setting properly.
Light remains on:
Check the correct wiring connection.
Check the TIME setting properly.
LED night light on-off twinkling :
Check any shield in front of sensor to cause
light reflection to the sensor, remove the shield
or change the installing location.
SPECIFICATIONS
Power Requirement
AC 100V ~ 240V, 50Hz/60Hz
External Lighting
Load
@ 230VAC
Up to 1000W Incandescent
or up to 400W Fluorescent
or up to 150W LED’s or CFL’s
Dusk to Dawn Night
Light
AC 100V ~ 240V, 50Hz/60Hz,
0.5W
Detection Angle
Up to 180° (at 20
°
C)
Detection Distance
Min. 12m at 20
°
C
Optional bracket’s
adjustable angle
Up to 45° to top down the PIR
head for detection area focus
Mounting Height
Recommended 1.5 ~ 1.8m for
wall mount, or 2.0 ~ 3.5m for
ceiling mount with swivel
bracket to adjust the best
detection coverage
Sensor Operation
Auto/Manual Override
Time Adjustment
Approx. 5 sec ~ 12 min
Lux Adjustment
Approx. 20 ~ 300 Lux
Warm Up Time
About 1 min.
Protection Class
II
Protection Degree
IP54
Safety CE
*Specifications are subject to change without prior notice.
Warning:
Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities.
Contact your local government for information
regarding the collection systems available.
If electrical appliances are disposed of in landfills or
dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging
your health and well-being.
When replacing old appliances with new once, the
retailer is legally obligated to take back your old
appliance for disposal at least for free of charge.
www.electra.pt