FIGURE 7
FIGURE 8
(12) For Ceiling mount, make use of the optional
bracket as a template to mark the position of two
screw holes on the ceiling, following the below
steps for ceiling installation :
Step 1 : use flat blade screw driver to tighten the
bracket joint (see drawing FIGURE 9).
Step 2 : screw the bracket onto ceiling surface
(see drawing FIGURE 9)
Step 3 : slide the sensor unit into the bracket to
hold the sensor unit solidly (see drawing FIGURE
9)
FIGURE 9
Step 4 : turn the bracket backward to adjust the
sensor position for the preferred detection
coverage (FIGURE 10)
FIGURE 10
Note : the maximum adjustable angle is 45
˚
The bracket joint may loosen after few times back
and forth adjustment, then use flat blade screw
driver to tighten the bracket joint again.
If want to remove the sensor unit from bracket,
just pull up the handle in the backside of bracket
a little with your thumb, then extract the sensor
unit from the bracket (FIGURE 11).
FIGURE 11
SETTING THE LIGHTING SYSTEM
(4)
TEST MODE
Turn the LUX knob and the TIME knob counter
clockwise to the edge at “T” mark which is the
TEST position. (FIGURE 12)
FIGURE 12
Turn on the wall switch. The light starts warm-up
for 1 minute after which it will automatically revert
to normal operation. During 1 minute warm-up
period, the light will stay on.
Walk through the detection area. The light turns
on when you move and turns off when you stop.
Wait for the light to turn off before moving again
to test the sensor.
(5)
TIME ADJUSTMENT
The TIME adjustment controls how long the light will
stay on after the motion has been detected.
Turn the TIME knob clockwise to increase (up to
about 12 minutes) the stay time or counter-clockwise
to decrease (down to about 5 seconds) the time
(FIGURE 13).
About 5 seconds About 12 minutes
FIGURE 13