background image

Page 11

www.elector-water-treatment.com

CLARIMAX 1200 DM pH+ LED – Water-filter-system for treatment of heating-system make-up water

3.5.1.4 Interval measurement (Short-term-mode)

The interval measurement is activated by a single press of the 
F-key. The status indicator flashes as long as the device is active. 
In this mode the measurement and the display stays on for 30 
seconds. Afterwards the device is deactivated automatically. This 
is a power-saving mode and therefore recommended for battery 
operation.

3.5.1.5 Continuous measurement

The continuous measurement mode is activated by pressing 
the F-buttom for approximately 3 seconds. The activation is 
confirmed by 3 successive acoustic signals. The status indicator 
stays on until the measurement mode is deactivated. In this 
mode the measurement and the display stay on constantly. For 
deactivation the F-key need to be pressed again for a longer time. 
The deactivation is also confirmed acoustically. The continuous 
measurement is only recommended in mains operation.

3.5.1.6 Battery capacity

The remaining battery capacity indicates the charge statues of 
the integrated rechargeable battery. As the number of highlighted 
LEDS decreases, the charge level decreases. (From green to red). 
The 3 red LEDS always stay on and represent a critical state of 
charge. The mains power adapter should be connected for further 
operation.

The display of the remaining battery capacity is activated by 

pressing the F key 5 times.

The status indicator flashes as follows: 3x flashing -> 2 seconds pause -> 3x flashing..... 

This mode stays on constantly. The conductivity measurement is switched off during thise mode. For 
deacitivation the F-key need to be pressed one time. The display returns to the previous mode.

3.5.1.7 Acoustic signal

As soon as the measurement enters the red area, an acoustic 
signal will sound. This remains active until the water quality is 
improved or it is deactivated manually.

The acoustic signla sounds in the following cycle: 5x tone -> 30 
sec pause -> 5x tone

To deactivate, press the F-key once.

 

1x

 

 

3 sec

 

 

5x

 

 

1x

 

Содержание Clarimax

Страница 1: ...User Guide Water Filter System for Treatment of Heating System Make Up Water Water Treatment ...

Страница 2: ...LARIMAX 1200 DM pH 5 2 Assembly Commissioning 2 1 System overview 6 2 2 Scope of delivery 7 2 3 Assembly of pressure container and container head 7 2 4 Assembly of inlet and outlet 7 3 Operation Handling 3 1 General note 8 3 2 Comissioning 8 3 3 Filling of heating systems 8 3 4 In line water correction 8 3 5 Capacity control 8 3 5 1 Integrated conductivity measurement 9 3 5 1 1 Battery and mains o...

Страница 3: ...ar Anyone working with this device must read this manual completely and follow the instructions In addition to the operating instructions the locally applicable regulations for accident prevention and for safe and professional work must be considered The manufacturer of the water treatment systems recommends to run a written documentation at the side of use The user should record the date of filli...

Страница 4: ...r system shall only be used by trained service technicians The manufacturer s specifications must be complied with for maintenance and or replacement of spare parts In case of unauthorized modifications at the device the CE declaration of the manufacturer expires The manufacturer takes no liability for damage caused by improper use Furthermore the warranty expires CLARIAMX must not be operated in ...

Страница 5: ...IN EN 1717 at the inlet of CLARIMAX If the water pressure is higher than 6 9 bar a pressure limiter should be installed at the inlet of the water treatment system It is generally recommended to use a pressure limiter when filling heating systems At the water inlet of the filter head a DVGW model tested backflow preventer according to DIN EIN 13959 is factory installed The installation of all parts...

Страница 6: ...r system 4 C to 50 C Ambient temperature for storage and transport dry new filter system 20 C to 50 C Nominal flow rate filter cartridge DM pH approx 300 l h at a pressure drop of 1 2 bar Weight dry wet 18 kg 24 kg Capacity 744 L at 500 µS cm conductivity of untreated tap water Dimensions Width Depth Height 288 255 550 mm Total system Operating position vertical Inlet connection G 3 4 Outlet conne...

Страница 7: ...peration of this device Attention Please pay attention to the technical data and to the operation and security instructions prior assembly and comissioning After storage below 0 C Note Store only new dry cartridges below 0 C the product need to be stored at room temperature for at least 24 hours Chapter 2 Assembly Comissioning 4 5 Page 6 www elector water treatment com CLARIMAX 1200 DM pH LED Wate...

Страница 8: ... head 3 counter clockwise lift it to the top to remove it from the housing Remove the red transport cap from the filter cartridge 2 and check the o ring seals for correct installation integrity and cleanliness Place cartridge 2 in pressure housing 1 Place both feet on the floor brackets 4 Place filter head 3 in position INSERT at pressure housing 1 Turn the filter head clockwise until it snaps bac...

Страница 9: ...in a single flow through principle The inlet of CLARIMAX is to be connected to the mains tap water supply and the outlet of CLARIMAX with the heating system Once the water has passed CLARIMAX it has the quality according to the guidelines We recommend to install a system separator or a compact filling armature at the inlet of the CLARIMAX filter system 3 4 In line water correction You even can tre...

Страница 10: ...n and charging of the battery pack 3 5 1 1 Battery and mains operation All functions are independently from the power supply The batteries are not charged in the state as delivered and therefore should be charged for at least 24 hours You can operate CLARIMAX either in mains supply mode with the power adapter or in battery mode A fully charged battery allows 48 hours operation You can find the con...

Страница 11: ...hausted and that a replacement of the cartridge will soon be necessary The quality of the treated water is still within the range of VDI 2035 The third area is divided into 3 red LEDs All LEDs start flashing accompanied by an acoustic signal The yellow LEDs turn of The filter cartridge is exhausted and need to be replaced The quality of the water does not comply with VDI 2035 anymore 3 5 1 3 Stand...

Страница 12: ...also confirmed acoustically The continuous measurement is only recommended in mains operation 3 5 1 6 Battery capacity The remaining battery capacity indicates the charge statues of the integrated rechargeable battery As the number of highlighted LEDS decreases the charge level decreases From green to red The 3 red LEDS always stay on and represent a critical state of charge The mains power adapte...

Страница 13: ... can be disposed in accordance with local regulations 3 7 Warranty The CLARIMAX 1200 DM pH LED filter system is subject to the statutory warranty of 2 years A warranty claim can only be asserted if all instructions in this manual are followed and observed Damage caused by improper changes use or grossly negligent damage to the product are not covered by the warranty Malfunctions due to incorrect o...

Страница 14: ...Page 13 www elector water treatment com CLARIMAX 1200 DM pH LED Water filter system for treatment of heating system make up water ...

Страница 15: ...Page 14 www elector water treatment com CLARIMAX 1200 DM pH LED Water filter system for treatment of heating system make up water ...

Страница 16: ...elector GmbH Düsseldorfer Straße 287 42327 Wuppertal Germany Phone 49 0 2058 1790863 Fax 49 0 2058 1790864 E Mail info elector gmbh de Internet www elector water treatment com Water Treatment ...

Отзывы: