The  digital  display  will  show 

‘NORMAL’

  and  the 

graphical  red  coloured  thermometer  will  be 
‘Animated’  whenever  the  heating  device  is 
switched 

‘ON’

 
 

 

 
The actual pool water temperature is shown in the upper area of the display. The required temperature is 
shown in the lower area of the display. The required water temperature can be adjusted by touching the 

‘UP  /  DOWN’

  touch  button  keys  until  the  required  temperature  is  displayed,  adjustments  are  in  0.1°C 

increments. 
 
Priority  of  Heating  is  a  function  that  ensures  your  pool  water  is  constantly  maintained  at  your  required 

temperature. When Priority of Heating is activated the Symbol 

will be displayed on the screen. 

 
The controller will then monitor the pool water temperature and start both the pool circulation pump and 
heating process when necessary. 
 

Time Switching Delay 

 

To  prevent  overheating of  the  switch  components  within  the  heating  device  caused  by frequent  on/  off 
switching (cycling) the controller has been pre-programmed with a time delay function. 
 
When time switching delay is activated the message display will show ‘

HEATER DELAY’

 for 2 minutes.    

 

Differential 

 

When the pool water has reached the required temperature the heating device will switch off and 
will  not  switch  back  on  until  the  water  temperature  has  fallen  0.6°C  below  the  required 
temperature

 

Operating Modes 

 
There are five operating modes: 
 

Normal 

Timer 

Priority 

Installation 

Standby 

 

 

 

 

 

 

Содержание Heatsmart PLUS

Страница 1: ...Heatsmart PLUS Touchscreen Heating Controller Installation Operating Manual...

Страница 2: ...6 INSTALLATION MODE 9 6 1 Language Setup 9 6 2 UNITS Setup 10 6 3 CLOCK Setup 11 6 4 TIMER Setup 11 6 5 Probe Calibration Setup 12 6 6 MODBUS Setup 13 6 7 FACTORY Setup 14 7 OPERATING MODES 14 7 1 St...

Страница 3: ...nd follow these instructions for proper installation maintenance and use Incorrect installation will affect your warranty The appliance is not to be used by children or by people with reduced physical...

Страница 4: ...art Plus has an upper keyhole screw hook located at the rear of the enclosure and 2 lower screw holes which are accessed after removing the 4 screws retaining the lower access cover at the front 2 1 M...

Страница 5: ...lock position according to the labelled positions Connection Explanation Terminal 1 Incoming Live 220 to 240V Terminal 2 Incoming Neutral Terminal 3 and 4 Primary Circuit Pump Output Connect the Boost...

Страница 6: ...6 3 WIRING DIAGRAM...

Страница 7: ...ing the controller button keys and graphical symbols 5 OPERATING INSTRUCTION On initial power up of the controller the digital display will be illuminated The heating device will only be switched On w...

Страница 8: ...g is activated the Symbol will be displayed on the screen The controller will then monitor the pool water temperature and start both the pool circulation pump and heating process when necessary Time S...

Страница 9: ...vert to the Normal mode and follow the same procedure as if first entering that mode the display will reflect this LANGUAGE English French German Spanish and Russian UNITS temperature units centigrade...

Страница 10: ...E touch the UP DOWN button keys again to display the next option which is UNITS touch the O K button key to select the display will show UNITS and CENTIGRADE touch the UP DOWN button keys to change to...

Страница 11: ...n revert back to show CLOCK touch the UP DOWN button keys until TIMER is displayed touch the O K button key to select TIMER 1 will be displayed touch the O K button key to select and SET TIMER 1 ON wi...

Страница 12: ...e periods and not the filtration pump cycles 6 5 Probe Calibration Setup After selecting EXIT for the timer setup the display will then show PROBE CAL touch the O K button key to select touch the UP D...

Страница 13: ...ddress touch the O K button key the display will revert back to show MODBUS SET ADDRESS Set Parity Touch the O K button key to select MODBUS SET PARITY and PARITY ODD will be displayed touch the UP DO...

Страница 14: ...BMS device 6 7 FACTORY Setup This category has restricted access 7 OPERATING MODES 7 1 Standby Operating Mode When in Standby mode the controller will display the text STANDBY Clock time and the Stan...

Страница 15: ...er display will be as shown below indicating the following information 1 Normal and Time 2 Actual water temperature 3 Required temperature 4 If the Flow switch does not detect sufficient flow the mess...

Страница 16: ...the controller will take a water temperature sample every hour and the message SAMPLING will be displayed If the pool water temperature is below the required temperature the controller will send a si...

Страница 17: ...ble Cause 2 Insufficient Flow The display will show NO FLOW if the flow switch has detected that the flow volume is below 4 000 litres per hour 4m h Check that the flow volume is greater than 4 000 li...

Страница 18: ...ring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of...

Страница 19: ...19 Notes...

Страница 20: ...e Hertfordshire SG1 2BH United Kingdom ___________________________________________________________________________ Customer Information ATTACH TO THE PRODUCT Company Name Contact Name Daytime Telephon...

Страница 21: ...21 Unit 11 Gunnels Wood Park Stevenage Herts SG1 2BH Sales elecro co uk www elecro co uk 44 0 1438 749474 Copyright MANE76HS EN Heatsmart Manual V1 01 01 2020 Elecro...

Отзывы: