8
Work Stations Calling
Suggested Macro Label: RUN
Command Sequence:
Copy VFO A frequency to VFO B. Copy VFO A filter and preamp
settings to VFO B. Exit SPLIT (TX on VFO A). Turn on RIT. Clear any
XIT setting. Clear any RIT offset. Normalize any filter shift.
Macro:
K3: SWT13;SWT13;FT0;RT1;XT0;RC;SWH58;
K4: AB3;FT0;RT1;XT0;RC;SW129;
DXing Macros
Calling on CW up 2 kHz
Suggested Macro Label: CW UP2
Command Sequence:
Set CW Mode. Set both VFOs on same frequency. Set filter and preamp
settings the same for both VFOs. Enter SPLIT. Set xmit frequency up 2
kHz. Clear any RIT setting. Clear any XIT setting. Lock VFO A
frequency. Toggle filter bandwidth.
Macro:
K3: MD3;SWT13;SWT13;FT1;UPB5;RT0;XT0;LK1;SWT58;
K4: MD3;AB3;FT1;VO$+2000;RT0;XT0;LK1;SW129;
Calling on CW up 5 kHz
Suggested Macro Label: CW UP5
Command Sequence:
Set CW Mode. Set both VFOs on same frequency. Set filter and preamp
settings the same for both VFOs. Enter SPLIT. Set xmit frequency up 5
kHz. Clear any RIT setting. Clear any XIT setting. Lock VFO A
frequency. Toggle filter bandwidth.
Macro:
K3: MD3;SWT13;SWT13;FT1;UPB7;RT0;XT0;LK1;SWT58;
K4: MD3;AB3;FT1;VO$+5000;RT0;XT0;LK1;SW129;
Calling on SSB up 5 kHz
Suggested Macro Label: SSB UP5
Command Sequence:
Set both VFOs on same frequency. Set filter and preamp settings the
same for both VFOs. Enter SPLIT. Set xmit frequency up 5 kHz. Clear
any RIT setting. Clear any XIT setting. Lock VFO A frequency. Toggle
filter bandwidth (K3 only). Set bandwidth to 2.1 kHz
Macro:
K3: SWT13;SWT13;FT1;UPB7;RT0;XT0;LK1;SWT58;BW0210;
K4: AB3;FT1;VO$+5000;RT0;XT0;LK1;BW0210;
Calling on SSB up 10 kHz
Suggested Macro Label: SSB UP10
Command Sequence:
Set both VFOs on same frequency. Set filter and preamp settings the same
for both VFOs. Enable split. Set xmit frequency up 10 kHz. Clear any RIT
setting. Clear any XIT setting. Lock VFO A frequency. Toggle filter
bandwidth (K3 only). Set bandwidth to 2.1 kHz
Macro:
K3: SWT13;SWT13;FT1;UPB7;UPB7;RT0;XT0;LK1;SWT58;BW0210;