Elecom PAR01 Скачать руководство пользователя страница 8

 

Activate the power

 

 
* Battery Power Check

 

 
When any keys around the central key is pressed, the device will check 
the battery power. If the power level is too low, the red LED will flash 
once  after  pressing.  Please  charge  the  device  through  micro  USB 
immediately.

 

 

* NWI

 

 
When the device is activated, the device will check is it already adding 
to  the  network?  If  doesn't,  it  will  auto  start  the  NWI  mode.  The  LED 
will flash in every second and continue 30 seconds. Until timeout or the 
device successful to add by controller. Users can hold down the central 
key,  then  press  the  top-right  key  three  times  within  1.5  seconds  to 
abort the NWI mode.

 

 
Over The Air (OTA) Firmware Update

 

 
The device support the Z-Wave firmware update via OTA. 
Let  the  controller  into  the  firmware  update  mode,  and  then  wake  up 
the device to start the update. 
After finish the firmware download, the LED will start flash in every 0.5 
second. Wait the LED stop flash, the firmware update is succeeded.   

 

Caution

: Do not running the OTA when the battery is running low. 

 
 

Spec

 

Power by Li 602025 battery. 
Signal (Frequency): 
 

868.40 MHz, 869.85 MHz(EU),   

 

908.40 MHz, 916.00 MHz(US),   

 

922~927 MHz(JP/TW), 

 

921.40 MHz, 919.80 MHz(ANZ), 

 

869.00 MHz(RU),   

   

865.20 MHz(IN),   

 

916.00 MHz(IL),   

 
RF Maximum Power: +5dBm 
 
Range:   
 

Minimum 40 meters indoor,    100 meters outdoor line of sight. 

 
Operating Temperature: 0

o

C ~ 40

o

For indoor use only. 
 
Specifications  subject  to  change  without  notice  due  to  continuing 
product improvement.

 

 

 
                                                                                                   

 

                                                                                                               
Disposal

 

 

 

This marking indicates that this product should not be 
disposed with other household wastes throughout the EU. 
To prevent possible harm to the environment or human 
health from uncontrolled waste disposal, recycle it 
responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the 
return and collection systems or contact the retailer where 
the product was purchased. They can take this product for 
environmental safe recycling.

 

Company of License Holder

Philio Technology Corporation 

Address of License Holder

8F., No.653-2, Zhongzheng Rd., Xinzhuang 

Содержание PAR01

Страница 1: ...ivate the device through battery then it can be added into the Z WaveTM network First make sure the primary controller is in the add mode And then power on the device The device will auto start the NW...

Страница 2: ...eTM network Get Started Step 1 Apply Power to PAR01 Open the PAR01 Casing InstallCR123 batteries PAR01 will detect the first applied power source to decide what Z Wave device role it will be in after...

Страница 3: ...a code that does not support Heat but Original air conditioner supports Heat Function please continue to try next code until the correct one is selected You can record down your Device Code for futur...

Страница 4: ...mmended IR Learning Mapping Table Parameter Number 25 Parameter Value Storage Location Thermostat Command IR Setting Storage in Celsius Unit Storage in Fahrenheit Unit 0 OFF OFF 1 ON Resume ON Resume...

Страница 5: ...D Display the mapping table with temperatures do not apply due to different type of IR Control Protocol However User may still use OFF ON RESUME DRY AUTO or FAN Key for Learning Because the POWER key...

Страница 6: ...the exter nal IR emitter cable to control each air conditioner Control Air Default 0x01 Conditioner 33 0x21 Range 0 to 1 0x00 or 0x01 1 SWING 0 0x00 Swing OFF function 1 0x01 Swing Auto Default Tempe...

Страница 7: ...ue is in Hexadecimal Numbering Format if the Gateway only support decimal numbering format please change it to decimal value accordingly Reset to Factory Default Press and Hold PROG button for 3 secon...

Страница 8: ...flash the firmware update is succeeded Caution Do not running the OTA when the battery is running low Spec Power by Li 602025 battery Signal Frequency 868 40 MHz 869 85 MHz EU 908 40 MHz 916 00 MHz US...

Страница 9: ...AIRWELL 276 670 598 433 432 AKAI 434 ALPIN 718 717 715 714 625 624 AMANA 836 AMCOR 716 668 665 664 663 662 AMERICOOL 430 AMVENT 811 46 APTON 513 839 525 524 523 522 521 520 519 517 516 515 514 508 67...

Страница 10: ...345 344 343 33 31 543 357 354 DAITSU 788 DANTEX 841 797 DEER SHUANGLU 592 1047 DELCHI 40 DELONGHI 819 818 787 91 46 503 13 DEMIRDOKUM 42 186 DIAMANT 106 DIMSTAL 545 DOCTOR 846 771 756 722 DONGBAO 652...

Страница 11: ...1061 835 830 655 417 1003 999 836 406 256 75 657 535 257 210 209 208 207 198 197 172 156 77 76 23 HAMILTON DIGITAL 186 HAWRIN 894 HERAN 807 40 429 56 421 869 868 867 866 851 850 565 562 550 55 HESSTA...

Страница 12: ...2 231 230 229 228 193 70 37 1117 982 981 884 883 882 881 500 355 351 237 186 176 153 93 57 35 340 347 MITSUBISHI HEAVY INDUSTRIES 346 322 319 317 316 278 1095 1084 574 568 356 329 243 36 1174 837 547...

Страница 13: ...UI 735 730 378 SANYO 586 46 1027 849 609 218 1141 1136 1135 1134 1133 1028 874 860 536 478 187 170 169 168 167 166 152 148 147 146 142 141 140 139 138 137 136 135 134 130 129 128 127 60 59 48 45 SASUK...

Страница 14: ...UNI AIR 743 723 VAILLANT 40 VESTEL 976 VIDEOCON 994 186 647 VIVAX 292 VOLTAS 641 409 377 46 5 4 VORTEX 598 WANBAO 1083 319 WEILI 582 WESTINGHOUSE 46 419 WESTPOINT 88 WHIRLPOOL 775 610 596 593 489 271...

Отзывы: