7
5.
MIST
4 levels from Low, Middle, Senior to High for different mist output. Changes are signalized by number of
illuminated segments
6.
TIMER
Settings from 1- 24 hours. 0 means cancelling the settings. 3 seconds after your settings, the timer function will
be counted down to work by minutes and will display with current humidity by turns for 5 seconds if having set
the humidity level.
7.
HUMIDISTAT
Settings from 40 -95RH% by 5RH%. 0 means cancelling the settings. 3 seconds after your settings, the humidistat
works. It stops when the current humidity is more than the setting level, but the fan motor will keep working for
5 minutes. And will operate when the current humidity is 2RH% less than the setting level.
8.
ANION
When the machine stands by, press the ANION button, it works whatever it is humidifying. The fan motor works
at the same time. If it is not humidifying, when the ANION is off, the fan motor stops. But if it is humidifying, when
the ANION is off, the fan motor still works.
9.
“Waterless”
1.Protection when waterless: When the tank is out of water, the Waterless lamp is on. And the machine stops.
Then the settings of TIMER and HUMIDISTAT will be cancelled. When filling the water, it should be reset for the
functions.
REPLACEMENT AND CLEANING OF A CERAMIC FILTER
Replacement and cleaning of a ceramic filter it is recommended to
clean the ceramic filter regularly (once a month) and to replace it
once a year.
In order to dismount the filter one needs to:
- make sure the appliance is unplugged,
- take hold of the handle
(4)
and take the tank
(3)
off the base of the appliance
(2)
- turn the tank, unscrew the cap (fig. 2)
- turn the filter counterclockwise,
The unit may operate without an assembled filter.
The filter can be purchased from ELDOM distributors.
1. Before cleaning, unplug the appliance.
2. It is recommended to clean the water tank regulary.
3. Do not immerse the humidifier in water or other liquid substance.
4. Do not use any aggressive cleaning agents.
5. It happens that in the base or in the ultrasound converter
(fig. 04)
a scale
is formed which can be removed by pouring 30% distilled vinegar on the
elements and leaving it there for 30 minutes.
6. For cleaning use the brush
(6)
located in the base
(3)
.
fig. 04
fig. 05
Filter significantly reduces adverse effects (e.g. scale deposition on
the ultrasound converter) resulting from the use of hard water.
CLEANING AND MAINTENANCE
PRACTICAL ADVICE
1. Do not direct the nozzle towards a wall. The moisture coming out of it may cause damage
of the paperwall, etc.
2. Excessive moisture in the room may cause condensation of water on window panes
and furniture. If this is the case, turn off the humidifier.
3. Do not use the humidifier in the rooms where the moisture level exceeds 80%.
4. Use tap water to fill the tank, however in case of hard tap water,
distilled water is recommended.
5. Do not use scent additives for water (essential oils, etc.)
6. When the humidifier is not used for a long time, its washing and drying is recommended.
Keep in a dry place.
7. It is recommended to place the humidifier at least one meter above a floor.