6.  ADDITIONAL INFORMATION

Limited Liability 

The buyer must agree that the system will reduce the risk of fire, theft, burglary or other dangers but does not guarantee against such 

events. “ELDES UAB” will not take any responsibility regarding personal or property or revenue loss while using the system. “ELDES UAB” 

liability according to local laws does not exceed value of the purchased system. “ELDES UAB” is not affiliated with any of the cellular provid-

ers, therefore is not responsible for the quality of cellular service. 

Manufacturer Warranty

 

The system carries a 24-month warranty by the manufacturer “ELDES UAB”. Warranty period starts from the day the system has been 

purchased by the end user. The warranty is valid only if the system has been used as intended, following all guidelines listed in the manual 

and within specified operating conditions. Receipt must be kept as a proof of purchase date. The warranty is voided if the system has 

been exposed to mechanical impact, chemicals, high humidity, fluids, corrosive and hazardous environment or other 

force majeure

 factors. 

SAFETY INSTRUCTIONS 

Please read and follow these safety guidelines to safeguard yourself and others: 
•  DO NOT use the system where it can interfere with other devices - such as medical devices 
•  DO NOT use the system in hazardous environments 
•  DO NOT expose the system to high humidity, chemical environments or mechanical impact 
•  DO NOT attempt to repair the system yourself - any repairs must be carried out by fully qualified personnel only 

The EWR2 can be powered by a 9-15V 300mA DC power supply unit, if no additional devices are connected. The device is not meant for 

outdoor use, i.e. you should use it inside a building and the power supply unit must be plugged into a standard Euro 2-pin socket or UK 

3-pin socket (depending on the version of power supply unit you have bought). When connecting the power supply, mind the polarity 

terminals. DO NOT switch the polarity terminals places. The main circuit should be protected by short circuit or over-current protection.

Please use the power supply that meets the EN 60950-1 standard. Any additional device you connect to the system, such as a comput-

er, must also be powered by an EN 60950-1 approved supply.  

Disconnect the mains power before installing. Never install or carry out maintenance during stormy weather. The electric socket that 

powers the device must be easily accessible.  

To switch the system off, unplug the external electric power supply or power down any other linked device that EWR2 is powered from. 

A blown fuse cannot be replaced by the user. The replacement fuse has to be of the kind indicated by the manufacturer (fuse F1 model 

– MINISMDC050F 0.5A).  

Copyright © “ELDES UAB”, 2015. All rights reserved 

It is strictly forbidden to copy and distribute information in this document or pass to a third party without an 

advanced written authorization from “ELDES UAB”. “ELDES UAB” reserves the right to update or modify this 

document and/or related products without a warning. Hereby, “ELDES UAB” declares that the wireless signal re-

peater EWR2 in compliance with the essential requirements and other relevant provisions of Directive 1999/5/

EC. The declaration of conformity may be consulted at: www.eldes.lt

The WEEE (Waste Electrical and Electronic Equipment) marking on this product (see left) or its documentation indicates that the 

product must not be disposed of together with household waste. To prevent possible harm to human health and/or the environ-

ment, the product must be disposed on in an approved and environmentally safe recycling process. For further information on 

how to dispose of this product correctly, contact the system supplier, or the local authority responsible for waste disposal in 

your area. 

Содержание EWR2

Страница 1: ...EWR2 WIRELESS SIGNAL REPEATER...

Страница 2: ...with the possibility to switch between antennas In addition EWR2 features 1 Wire input for Dallas DS18S20 DS18B20 digital temperature sensor connection and allows to add up to 8 temperature sensors fo...

Страница 3: ...rating temperatures 20 55 C Humidity 0 90 RH 0 40 C non condensing Dimensions 94x137x25mm Compatible with alarm systems ELDES wireless 2 2 Main Unit and LED Indicator Functionality LED indicator funct...

Страница 4: ...g the position of alarm system s wireless antenna might also improve the results When placing the wireless antenna please follow the recommendations Wireless antenna 3 Never install in the following l...

Страница 5: ...bove their icons Wireless devices with a bad wireless signal level detected by EWR2 are indicated by the blue stripe at the top left corner of their icons Green stripe Wireless device is communicating...

Страница 6: ...ed regardless of system being armed or disarmed There are 2 ways to detect tamper violation on EWR2 By tamper switch EWR2 comes equipped with 2 built in tamper switches intended for enclosure supervis...

Страница 7: ...tion Tool software s HELP section or ESIM364 user manual 12 Z1 COM 3V DATA COM DC COM Z2 GND 3V DATA Dallas Temperature sensor GND DATA 3V Antenna Switching EWR2 comes equipped with the internal wirel...

Страница 8: ...d ELDES alarm system is below 18 EWR2 will connect to the device and start expand ing it s signal range by transferring the data from a wireless device to ELDES alarm system and the other way around W...

Страница 9: ...EWR2 EWR2 WIRELESS DEVICE WIRELESS DEVICE WIRELESS DEVICE EWR2 16 EWR2 Setup Time The time of connection of EWR2 to a wireless device may depend on the device type In general it takes approximately 1...

Страница 10: ...ions When the signal level between a wireless device and ELDES alarm system rises to 51 or higher EWR2 ALARM SYSTEM WIRELESS DEVICE EWR2 ALARM SYSTEM WIRELESS DEVICE EWR2 ALARM SYSTEM WIRELESS DEVICE...

Страница 11: ...signal Level 18 EWR2 EWR2 WIRELESS DEVICE WIRELESS DEVICE WIRELESS DEVICE EWR2 20 Enabling disabling EWR2 repeating functionality After EWR2 repeater s is successfully bound to the alarm system it is...

Страница 12: ...ill find the bin file Otherwise open My Computer and look for CRP DISABLED drive 5 Delete the bin file found in the drive 6 Copy the new firmware bin file to the same window 7 Unplug USB cable 8 Firmw...

Страница 13: ...tandard Euro 2 pin socket or UK 3 pin socket depending on the version of power supply unit you have bought When connecting the power supply mind the polarity terminals DO NOT switch the polarity termi...

Страница 14: ...MadeintheEuropeanUnion www eldes lt...

Отзывы: