Eldes EWK2 Скачать руководство пользователя страница 5

55

EN

EWK2/EWK2A Manual v.1.2

4. PANIC BUTTON

By default, EWK2A keyfob supports a Panic Button feature allowing to cause an alarm at any time when the keyfob button is pressed. 

EWK2 keyfob may support a Panic Button feature as well. This feature that can be configured using ELDES Configuration Tool software by 

creating a virtual zone of Panic/Silent or 24-Hour type and assigning it to Virtual Alarm option. The Panic Button feature can be set up on 

any button of EWK2.

5. BATTERY REPLACEMENT

1.   Open EWK2/EWK2A enclosure. 

2.   Remove the old battery from the battery slot. 

3.   Postition the new battery according to the appropriate battery slot positive terminal indicated. 

4.   Insert the battery into the battery slot. 

5.   Battery replaced. 

See 

3. INSTALLATION

 for more details. 

ATTENTION: 

  Only CR2032 3V battery can be used. Install only new, high quality and unexpired batteries.

ATTENTION: 

  The battery must be removed if the device is not in use. 

ATTENTION: 

   In order to avoid fire or explosion hazards, the system must be used only with approved battery. Special care must be 

taken when connecting positive and negative battery terminals. Dispose old batteries only into special collection sites. Do not charge, 

disassemble, heat or incinerate old batteries. 

NOTE: 

  The system sends an SMS message to the listed user phone number as soon as the battery level runs below 5%.

NOTE: 

  The battery status can be monitored in real-time using 

ELDES Configuration Tool

 software.

6. RESTORING DEFAULT PARAMETERS

EWK2

1. Press and hold  

   and    

  buttons simultaneously.  

2. Hold the buttons pressed until LED indicator and the buzzer provide several short flashes and beeps simultaneously. 
3. Release the buttons. 
4. Parameters restored to default. 

EWK2A

1. Press and hold the lower side of the button. 
2. Hold the button pressed until LED indicator and the buzzer provide several short flashes and beeps simultaneously. 
3. Release the button. 
4. Parameters restored to default.

Отзывы: