background image

V

V

I

I

P

P

C

C

L

L

A

A

M

M

P

P

M

M

I

I

N

N

I

I

§

  

Cable resistance compensation ( zero) 

To measure low resistance values, measure the cable resistance first.

-Short-circuit the cables.

-

Press and hold the HOLD key

 until zero appears on the display.The cable resistance value will then be

memorised and subtracted from the value of the resistance measured later.

Note

: If the value measured is higher than 2 

W

, this correction is stopped and the memorised correction value is reset to

zero.

(1) with compensation for measurement cable resistance

MIN/ MAX Mode:

-Accuracy: same as previous table +0.2% L

-Capture time: 100 ms typ.

3.4 Resistance measurements (W

,

)

1. 

Connect the measurement cables to the unit terminals.

2. 

Set the rotary switch to position "        " and press once on the yellow key: The     symbol is no longer displayed.

3.

 Connect the unit to the circuit to be tested. Range selection is automatic. To measure low resistance with accuracy,

    compensate the cable measurement resistance (see § 3.3). Above 40 

W

, the display indicates 

OL

.

Display range

400 W

Measuring range

Accuracy (1)

Resolution

Open circuit voltage

Protection

0,0  à 399,9

W

1% L ± 2 pto

0,1

 

W

,

300

 

µA

Measuring current

3,2 V

500V AC o 750V

(DC or peak)

MIN/ MAX Mode:

- Accuracy: same as previous table +0.2% L

- Capture time: 100 ms typ.

3.5 Semi-Conductor Test (

)

1.  

Connect the measurement leads to the instrument’s terminals, complying with the polarities indicated: red lead

     on the “+” terminal and black lead on the “COM” terminal.

2.

  Set the rotary switch to " 

" position and press twice on the yellow key: The 

symbol is displayed.

3.

  Connect the unit to the semi-conductor (junction) to be tested.

     The measurement current moves from the “+” terminals to the “COM” terminal. It corresponds to the direct

     testing of the semi-conductor junction.

     - Short-circuit junction:

 audio indication for a threshold <0.050V

     - Cut or reversed junction

 (or threshold > 3.2 V) : 

OL 

displayed

Display range

4V

Measuring range

Accuracy

Resolution

Protection

0,000 a 3,199V

1% L ± 2 pto

1mV

Measuring current (1) da 2mA a 4mA

500V AC o 750V (DC or peak)

(1) for the voltage measured

Display range

40 V

400 V

4000 V (1)

Measuring

range

Accuracy

Resolution

Measuring

current (1)

Protection

0,2 V à

39,99 V

40,0 V à

399,9 V

400 à 600 V

400 à 900

10 mV

0,1V

1V

1M

W

600 V AC ou DC

1% L ± 2 pto

1% L ± 2 pto

1% L ± 5 pto

4

Содержание VIP CLAMP MINI Series

Страница 1: ...e clamp box is not properly closed Before any measurement check the proper positioning of the cables and switch When measuring current check for proper alignement of the conductor in relation to the m...

Страница 2: ...ement zer 9 3 12 5 Manual selection of AC DC or AC DC mode 9 3 12 6 Selections possible in continuity function 9 3 12 7 Selectione OF INRUSH function 9 3 12 8 Suppression of automatic stop 9 3 12 9 Ac...

Страница 3: ...ty measurement by use of the yellow resistance key and semi conductor test A Measurement of DC and AC voltages rms value PF Measurement of active reactive and apparent var W powers and power factor in...

Страница 4: ...tal display The liquid crystal display includes the digital display of the measured values the related units and symbols Digital display 4 digits 9999 points 3 decimal points and signs DC and peak mea...

Страница 5: ...V 3 Connect the assembly to the voltage source to be measured making sure if possible that this voltage does not exceed the maximum acceptable limits see table below Range switching and AC DC selecti...

Страница 6: ...asuring range Accuracy 1 Resolution Open circuit voltage Protection 0 0 399 9W 1 L 2 pto 0 1 W 300 A Measuring current 3 2 V 500V AC o 750V DC or peak MIN MAX Mode Accuracy same as previous table 0 2...

Страница 7: ...o in DC Repeatability of the measurement after several consecutive closings of the clamp 0 3 typical MIN MAX Mode Accuracy same as previous table 0 2 L Capture time 100 ms typ PEAK Mode Accuracy same...

Страница 8: ...3f arrow on the jaws must be directed in the direction of power circulation from the source to the load In which case the sign corresponds to power consumed by the load the sign corresponds to power s...

Страница 9: ...he frequency measurement is performed on the voltage signal 1 Perform a short pressing on the Hz key the display shows the frequency of the measured signal 2 Pressing again returns to the previously d...

Страница 10: ...essing unlocks the display 3 12 2 Preselection of MIN MAX mode A short pressing on the HOLD key then on the MIN MAX key preselects the MIN MAX mode A second pressing on the HOLD key makes the MIN MAX...

Страница 11: ...12 8 Suppression of automatic stop Hold the HOLD key pressed and bring the rotary switch from the OFF position to the position The unit emits a double beep then the symbol flashes The selected configu...

Страница 12: ...x 10 s measurements 6 Battery charge indicator Flashing charge life 1 h Fixed Change battery Automatic OFF after 10 minutes with no action on the switch or the keys reactivation by switching from the...

Страница 13: ...V V I I P P C C L L A A M M P P M M I I N N I I 4 6 Variations in operating range 11...

Страница 14: ...t the top of the battery cover rear of the clamp and push the battery cover upwards Replace the used battery by a 9 V battery type LF22 observe the polarities Install the battery in its housing then i...

Страница 15: ...V V I I P P C C L L A A M M P P M M I I N N I I APPENDIX APPENDIX 13...

Отзывы: