background image

 

SnowClear Installation, Operator & Maintenance Manual

 

20 

Maintenance Instructions

 

 

1.

 

Disconnect the power supply at the circuit breaker panel and ensure the heating elements are cool before 
performing cleaning, minor servicing or maintenance. These tasks should only be performed by a licensed 
and qualified electrician. 

 

2.

 

Snow melting efficiency may decrease if the reflectors become dirty due to the build-up of contaminants 
from  the  environment.  Daily  visual  inspection  and  maintenance  are  important  to  ensure  maximum 
melting  capability  throughout  the  winter  season.  Cleaning  of  exterior  casing  and  removal  of  foreign 
matter may be required. 

 

3.

 

After  the  winter  season,  it  is  recommended  to  clean  the  product  with  a  soft  cloth,  gently  wiping  the 
outside surfaces of the unit with a mild detergent to remove built-up. Wipe all the detergent off the unit. 

 

4.

 

Due to the nature of the heating elements, they will need to be replaced within the life span of the unit. 
For heating element replacement, please contact the retailer from where you purchased the unit. The 
heating element should only be replaced by a licensed and qualified electrician. Gloves must be worn 
during  heating  element  replacement.  Any  fingerprints  or  grease  on  the  heating  element  surface  may 
shorten the life span of the heating element.  

 

5.

 

Heating Element Replacement- Licensed and qualified electrician to perform this task. 

a)

 

Disconnect the unit from the supply circuit.  

b)

 

Unscrew the grill holders and remove the grill. 

c)

 

Remove both side reflectors with a gentle pulling motion. 

d)

 

Locate the high temperature porcelain wire connectors. Use a counter clockwise motion to unwind 
the  wire  connector  and  expose  the  wire  connection.  Separate  the  wires.  Remove  the  insulation 
sleeve covering the heating element wire. Save this sleeve. 

e)

 

Unscrew the heating element holder located at each end of the heating element. Remove the burnt-
out heating element. 

f)

 

Wear clean soft gloves and remove the protective covering from around the new heating element. 

g)

 

Place the new heating element in the base holder and attach the top heating element holder. Ensure 
the  heating  element  is  securely  fastened.  Replace  the  insulation  sleeve  over  the  new  heating 
element wire.  

h)

 

Strip 14.3mm (0.56 inch) of insulation from the  stranded wire  ends to be  connected. Hold wires 
together with ends even. Bend wire tips together. Do no pre-twist wire. Push wires into the porcelain 
wire connector and screw connector clockwise onto the wire  until tight. Check that all wires are 
gripped tightly by the connector. Slide the insulation sleeve over the bare heating element wire. 

i)

 

Slide  both  end  reflectors  back  into  place,  ensuring  that  the  wire  connections  are  behind  the 
reflectors.  

j)

 

Replace the grill and grill holder. 

k)

 

Power may now be restored to the unit. 

 

 

 

 

 

 

MAINTENANCE INSTRUCTIONS 

Содержание SnowClear TK-C4000

Страница 1: ..._________________ Serial TK________________________ INSTALLATION OPERATOR MAINTENANCE MANUAL Table of Contents Important Instructions 2 Safety Instructions 2 Specifications 5 Installation Instructions...

Страница 2: ...Melter s warranty Please record the serial number on the front of the manual Having this number on hand is important when calling to order replacement parts Safety Instructions Follow Important Safety...

Страница 3: ...intenance SnowClear Overhead Melter must be properly installed by a licensed and qualified electrician before using Ensure they fully understand the procedure and are qualified to undertake any mainte...

Страница 4: ...inspections Risk of Fire High temperature risk of fire keep electrical cords drapery furnishings and other combustibles at least 0 9 m 3 feet from the front on the heater and away from the side and r...

Страница 5: ...ngle phase 208 240VAC 4000 W Heating Elements Four ceramic special coating halogen lamps Power Supply Connection Minimum 10 AWG 30 A 3 Conductor Cable Conductor cable is not supplied Continuous Run Ti...

Страница 6: ...ng element to cool before touching Do not touch the glass part of the heating element with bare hands as grease including fingerprints may cause the heating element to burn out prematurely Gloves shou...

Страница 7: ...SnowClear Installation Operator Maintenance Manual 7 Terminal Block and Wiring Guidelines Main Unit with Mounting Bracket M4 screw ring terminal...

Страница 8: ...erhead Melter is designed for domestic or commerical snow melting application in an outdoor area and should not be used or modified for any other purpose 8 Before starting installation check that the...

Страница 9: ...ng off a roof will not damage the product Step 1 Mount the bracket to the ceiling wall pole at the designated height see 11 under Installation Instructions Step 2 Install the unit to the bracket and s...

Страница 10: ...ght Install the unit 2 5m to 3m 8 2 to 10 feet above the ground Installation Angle Adjust the unit in the vertical inclination angle between 0 and 20 If the unit is to be installed on an incline ensur...

Страница 11: ...l screws are tight and that the unit is secure When installing the unit on a wood or thin wall or ceiling reinforcing the wall or ceiling with a steel plate is required to ensure that the weight of th...

Страница 12: ...r pole installation use the four holes indicated below Mount Unit to Bracket Wall Installation Use the two top holes on the main unit bracket to join the unit to the holding bracket 4 sets of M8 bolts...

Страница 13: ...iling Reinforce the attachment area with a steel plate to ensure that the unit s weight will be supported Ceiling Installation Angled For angled wall installation move the main unit upwards to 20 degr...

Страница 14: ...Angled For angled wall installation move the main unit upwards to 20 degrees Power Cable Wiring Guide Ensure the electrical cable dose not touch the unit Bend the electrical cable down to prevent wat...

Страница 15: ...trol plus a single 30 amp relay The DS 2C is recommended for one or more units Two or more units requires the DS 2C and one or more contactors Install the Danfoss Rain Snow Sensor Controller DS 2C acc...

Страница 16: ...SnowClear Installation Operator Maintenance Manual 16 One SnowClear Overhead Melter Unit Two SnowClear Overhead Melter Units...

Страница 17: ...SnowClear Installation Operator Maintenance Manual 17 Three to Six SnowClear Overhead Melter Units...

Страница 18: ...SnowClear Installation Operator Maintenance Manual 18 Seven to Twelve SnowClear Overhead Melter Units...

Страница 19: ...ctrical shock Installation and direct connection of the power contractor must be done by a licensed and qualified electrician Scope of Application per unit SnowClear is a far infrared overhead snow me...

Страница 20: ...eating Element Replacement Licensed and qualified electrician to perform this task a Disconnect the unit from the supply circuit b Unscrew the grill holders and remove the grill c Remove both side ref...

Страница 21: ...head melter under warranty will not extend the period of the warranty Any parts which are returned to Trecan Combustion Limited will become the property of Trecan Combustion Limited This limited warra...

Страница 22: ...ity or warranty of fitness for a particular purpose are limited to the duration of this warranty This limitation is not allowed by some States Provinces or Territories and so this limitation may not a...

Отзывы: