background image

E

D

C

B

F

A

8

7

6

5

4

3

2

1

Blatt
Page
Page

Schema Nr.:
Drawing No.:
Schéma No:

Artikelnummer
Article Number

Numéro article

Bearb.
User
Utilisateur

Datum
date
Date

Am/

ECN:

=B
+SB

11

1b

N8.5800-N9.10.400 L-E/BT

14071787

LH

28.03.2013

+B

+SBx

=ext.
+ext.

/2.D1

/2.D1

3

M

~

U1

V1

W1

W2

U2

V2

/2.A1

/3.B2

/3.B2

/3.C2

/3.C2

/5.A1

/5.C2

/5.C2

/5.C2

I> I> I>

/2.D1

/2.A1

3

M

~

U1

V1

W1

W2

U2

V2

/4.A5

/4.B5

N

0

7

0

6

0

5

-X

B

1

1

2

-1F010.1

PE

PE

-XS.230:PE

U

1

V

1

W

1

P

E

V

2

U

2

W

2

A

S

-P

E

+ -

-1B353

04

L

N

L1
L2
L3

PE

PE

N

PE

L

1

2

3

4

L

M31

M31-N

LDW

BMG

-X2B:313

LSB

11

12 14

-1K31..

A1

A2

-1K31..

S

C

R

S

C

R

AS

-P

E

PE

N

-XS.230

L.

N.

PE.

1

2

-X

B

1

S

C

R

1

2

3

4

5

6

-1F11.

13

14

21

-1F11.

22

SMP

L010

-XS.230:L

A1

A2

U

1

V

1

W

1

P

E

V

2

U

2

W

2

A

S

-P

E

M11

M11-N

0

1

-X

B

1

0

2

0

3

1

2

3

4

5

6

-1K11.

+SB

B 10A

!-1-!

-1T311

40

0V

A

C

-1M31

2

4

V

-1X01

max 10A

!-6-!

OPTION fan speed control

+ext.

-F???

2

3

0

V

/5

0

H

z

3

~

4

0

0

V

/5

0

H

z

40

0V

ac

23

0V

ac

-T?

!-2-!

f

!-5-!

!-3-!

40

0V

A

C

23

0V

A

C

gG ?A

-Q?

N

am

ur

 -

N

am

ur

 +

sp

ee

4-

20

m

A

sp

ee

G

N

D

4

-1A05

Lamtec 

VSM

11

12

1

2

6

5

4

3

7 8 9

5 6

LSB

LSB

1   2   3   4   5   6   7   8

R

DIL - ON

U1

V1
W1

PE

U2

W2

PE

fvar

25...50Hz

ABB ACH550

50Hz

10

13

11
12

21

20

19

1

3

2

V2

DIP J1

AI1 AI2

4-20 mA

0-10 V

ON

1

2

24V

GND

H

L

24V
GND
H
L

-F?

!-4-!

gG <=16A

s=

0,

75

m

m

² I

r=

1,

2A

s=1,5mm² Ir=10A

!-10-!

Icc<10000A

Icc<2000A

Icc>=52A (t<<0,4s)

s=1,5mm² Ir=10A

40

0V

A

C

-1M11

Pm

11kW
15kW
18,5kW

22kW

-1M31

Ir

20,0A
26,5A

39,5A

33,0A

Size

N8.5800 L-E
N8.7100 L-E
N9.8700 L-E
N9.10400 L-E

Nextron

-F???

gG 35A
gG 55A
gG 55A
gG 63A

gG ?A >=

GV2-ME22
GV2-ME32
GV3-P40
GV3-P50

20,0A
26,5A

39,5A

33,0A

3kW

LC1-D09P7

3kW

LC1-D09P7

4kW

LC1-D09P7

GV2-ME14

6,1A

GV2-ME14

6,1A

GV2-ME14

7,8A

-1F11?

-1M11

Ir

-1K11

Pm

Type -1F31

Ir

6,1A

GV2-ME14

LC1-D09P7

3kW

ACH550-01-023A-4
ACH550-01-031A-4
ACH550-01-038A-4
ACH550-01-045A-4

-1T311?

Type

Содержание N8 L-E/BT3 Series

Страница 1: ...ve earth conections and potential conectors The min conductor size schall be 0 75mm for cables with 1 or 2 and 0 5mm for cables with more than 2 conductors or with screening main potential conductors 16mm Power cables schould be dimensioned by IEC 60364 respect thermical mechanical and chemical conditions Motor power cables from power converters VSD have to be screened earthed and have to be separ...

Страница 2: ...MP L010 XS 230 L 01 XB1 02 03 1 2 3 4 5 6 1K11 1 1 2 3 4 5 6 1K31 H 1 2 3 4 5 6 1K31 D 1 2 3 4 5 6 1K31 S 13 14 21 22 B 10A 1 400VAC 230VAC 1X01 max 10A 6 SB ext F F 230V 50Hz 3 400V 50Hz 400Vac 230Vac T 2 f 5 3 400VAC 230VAC gG 16A gG A Q s 0 75mm Ir 1 2A s 1 5mm Ir 10A 10 4 Icc 10000A Icc 2000A Icc 52A t 0 4s s 1 5mm Ir 10A 1M11 400VAC 400VAC 1M31 L1 L2 L3 GY BK BN BU WH RD L1 L2 L3 Pm 11kW 15kW...

Страница 3: ...AC 1M31 24V 1X01 max 10A 6 OPTION fan speed control ext F 230V 50Hz 3 400V 50Hz 400Vac 230Vac T 2 f 5 3 400VAC 230VAC gG A Q Namur Namur speed 4 20mA speed GND 4 1A05 Lamtec VSM 11 12 1 2 6 5 4 3 7 8 9 5 6 LSB LSB 1 2 3 4 5 6 7 8 R DIL ON U1 V1 W1 PE U2 W2 PE fvar 25 50Hz ABB ACH550 50Hz 10 13 11 12 21 20 19 1 3 2 V2 DIP J1 AI1 AI2 4 20 mA 0 10 V ON 1 2 24V GND H L 24V GND H L F 4 gG 16A s 0 75mm ...

Страница 4: ... TL 05 06 AS PE feedback 5A04 8 l feedback 5A04 7 l PE PE PE PE PE PE 54 53 RKRon SMP 1F11 1 22 1F11 22 07 XB4 L010 1F11 1 21 1F11 21 XB2 Sicherheitskette Kessel boiler safety circuit Chaine de sécurité chaudière S 2A01 Freigabe Regelkette release control circuit Liberation de la régulation Brennerstart ext burner start ext Marche brûleur ext 2A02 Brennerlast Burner load Charge brûleur N PE L Ölsi...

Страница 5: ...384 380 X2B 381 X3B PE XS 230 PE L XS230 AS PE T RKR RKRon LoadR Load Load AS PE T Q Y1 XT Q13 Q14 Y2 N PE PE TN TL AS PE T PE AS PE T AS PE T AS PE T PE AS PE T N XS 230 PE XS 230 3B374 PE XS 230 Lamtec BT320 A01 X32 AIR servo 3K39 2A01 230VAC 230VAC 230VAC 6 X25 1 X25 2 X25 3 X20 1 X20 3 X20 4 X21 1 X21 2 X08 2 X08 1 S N PE ION L LDR LDR L S X20 2 3B378 230VAC 230VAC GNDDC 24VDC 24VDC 24VDC K1 2...

Страница 6: ... 1 PE Un 4K156 PE PE PE 2 1 PE Un 4K154 N 1 PE 2 3 P 4F131 1 4 4 4 PE 2 4 131 X2B L 2 1 PE 4T110 HV HV 1 PE 2 3 P 4F121 1 4 4 4 3 4 132 M11 M11 N N N XS 230 N OSKe1 XB2 115 X2B L 144 N 145 154 146 156 Lamtec BT320 4K19 V1 V3 V2 V1 V2 V3 ZV S PE S N A01 X31 TTL_BUS 230VAC 2A01 L N PE 6 H L 24V GND 4 TTL X22 1 X22 2 X22 3 X06 1 X06 2 X06 3 X05 1 X05 2 X05 3 X01 1 X01 3 N X02 1 X02 3 N X03 1 PE X03 2...

Страница 7: ...07 Lamtec LTx Transmitter MASTER 4 L PE N 230V 50Hz VA Lamtec Probe Lamtec SAK cable 2m 1 bk 2 gy 3 wh 4 wh 1 bk 2 gy 3 wh 4 wh COe O2 COe Heating Heating 3 5 bu O2 2 5 bu cable 0 75mm 20m cable 1 5mm 50m cable 1 5mm 20m cable 2 5mm 50m 5 X XKS1D cable 2m 7 230V AC 24VDC 24VDC 24VDC OUT Lamtec LTx Transmitter SLAVE Probe 230V AC LSB 24VDC 5A07 1 Lamtec Probe cable 2m 5 X 1 OPTION LSB Lamtec LCM Ca...

Страница 8: ...5800 N9 10 400 L E BT 14071787 LH 28 03 2013 ext ext ProfiBus Master 5 B5 5 B5 5 B5 5 B5 5 C5 5 C5 5 B5 5 C5 SC SC 0V 24V CH CL CL CH AS AS AS 1 10 6XA09 1 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9 10 SHIELD 10 AS OPTION ProfiBus 17 24V 10 Can H 11 Can L 12 Can H 13 Can L 18 GND 6A09 1 6 B2 7 A2 8 B1 9 A1 ProfiBus 9 6 5 1 ProfiBus 1 2 3 4 5 6 R DIL ON LSB 24V GND H L LSB 24V GND H L ...

Страница 9: ...Date Am ECN PI 11 7 N8 5800 N9 10 400 L E BT 14071787 LH 28 03 2013 M L M M M L H P P P IR UV Verbrennungsluft Combustion air Air de combustion 3K39 3F311 5A07 Öl Rücklauf oil reflow huile retour 4T110 Öl Vorlauf oil preflow huile départ 4F121 4K144 1M11 4K156 4K19 4K154 3B378 1M31 1B353 f 50Hz 1T311 OPTION fan speed control 4K146 4F131 OPTION PED 3B374 ...

Страница 10: ...rol Régulation O2 réglage O2 CO 1F010 Sicherungsautomat Steuersicherung Circuit breaker Control fuse Coupe circuit Fusible de commande 1F31 Motorschutzschalter motor circuit breaker 1K31 Motorsteuerung motor control Disjoncteur thermique moteur Contacteur moteur 2S058 Schalter lokal fern Switch local remote Interrupteur locale télécommande 1X01 Steckdose 230V 50Hz max 10A ohne Anschluss Plug in so...

Страница 11: ...puissance Régulation O2 démandé 230V 50Hz Einspeisung entsprechend den örtlichen Vorschriften N Leiter erden TN S Netz Steuerspg 230V 50Hz Spannungsversorgung Kurzschluss Schleifenimpedanz Grenzwert Xmin 0 3 OHM Icc 2000A Einspeisung berücksichtige Potentialausgleich am Schaltschrank Xmax 3 OHM Icc 52A t 0 4sec berücksichtige Steuerleitungen angeschlossen an XB2 XB3 XB4 10 230V 50Hz Voltage supply...

Отзывы: