Safety instructions  

 

The  SMSB242/SMSB482  contains  the  latest  generation  of  GSM  quad-band  module.  The  instructions  contained  in  this 
manual must be precisely observed for correct installation and proper use. 

 

Do  not  install  the  SMSB242/SMSB482  in  the  vicinity  of  pacemakers,  hearing  aids  or  medical  devices  in  general.  The 
SMSB242/SMSB482 can interfere with the correct operation of these devices. 

 

The SMSB242/SMSB482 may not be installed in aircraft. 

 

The SMSB242/SMSB482 may not be operated in atmospheres with gas or flammable gases. 

 

The SMSB242/SMSB482 operates using a wireless signal. No wireless operator can guarantee a connection at all times. 
For this reason the SMSB242/SMSB482 cannot be used with emergency call systems. 

Installation 

For the safety of the user and in order to ensure the fault-free operation of the SMSB242/SMSB482, the device may only be in-
stalled by qualified experts. The specifications listed below must also be observed. 

Environmental conditions 

The SMSB242/SMSB482 (the device and all connected cables) must be installed in locations which satisfy the following condi-
tions: 

 

No dust, no moisture, no high temperatures 

 

No direct solar radiation 

 

No devices which radiate heat 

 

No objects which generate a strong electromagnetic field 

 

No corrosive liquids or chemical substances 

 

The  SMSB242/SMSB482  was  designed  for  operation  at  temperatures  between  and  45  °C  (standard  operating  tempera-
ture). 

 

Sudden changes in temperature and/or humidity must be avoided. 

Protection class 

The following protection class must be ensured with the installation of theSMSB242/SMSB482: 

 

IP40: Minimum protection class which must always be ensured 

 

IP54: Protection class which only has to be ensured for use outdoors 

Supply  

The following specifications must be observed: 

 

Do not use any cables with a length greater than 2m 

 

The external power supply unit must conform to European standard EN60950 (Electrical safety) 

 

Ensure the correct polarity (+/-) 

Digital and analogue inputs 

The following specifications must be observed: 

 

Only zero-potential contacts may be connected. If analogue sensors are connected, they must be suitable for this purpose 
and certified. 

 

Do not use any cables with a length greater than 2m. 

 

Do not connect analogue inputs to sources of voltage. 

 

Do not install cables near electromagnetic fields; otherwise use shielded cable. 

 

Ensure the correct polarity for the analogue inputs. 

 

Relay outputs  

 

Observe the technical data in the corresponding chapter. 

 

Do not use any cables with a length greater than 2m. 

Содержание SMSB242

Страница 1: ...User s manual SMSB242 SMSB482 SMS Switch Butler...

Страница 2: ...2...

Страница 3: ...ply new functionality or new instructions for products already sold The manufac turer cannot be held liable for loss or damage direct or indirect which may result from use of the product The product i...

Страница 4: ...roni cally and physically including photocopies or saving are only permitted to the user for personal use and prohibited in all other cases without special written authorization The use copying modifi...

Страница 5: ...solar radiation No devices which radiate heat No objects which generate a strong electromagnetic field No corrosive liquids or chemical substances The SMSB242 SMSB482 was designed for operation at tem...

Страница 6: ...6 Use the same voltage level for all relays With high voltage circuits only the phase conductor may be connected via the re lay contacts...

Страница 7: ...gue inputs common earth 9 Code switch for analogue inputs 30 4 59 mm 61 70 mm 45 40 mm 35 42 mm Mo TuWeThFrSaSu IN8 IN4 GSM GPRS IN1 IN2 IN3 IN5 IN6 IN7 RE1 RE2 RE3 RE4 AN1 AN2 SMSB482 I O 2 1 7 6 8 5...

Страница 8: ...NPUTS 12 24V 1000mA NC COM NO NC COM NO NC COM NO NC COM NO RELAY 1 RELAY 2 RELAY 3 RELAY 4 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 LOAD1 LOAD2 LOAD3 LOAD4 For each relay the output maximum current is 5A Tota...

Страница 9: ...osed contacts The device is password protected and can store and manage up to eight users In order to simplify installation and operation of the device the SMSB242 SMSB482 is equipped with a large int...

Страница 10: ...The installation software of the SMSB242 SMSB482 is stored in the Micro SD mass storage In order to start the butler in MSD mode and install the software you must proceed as follows 1 Switch off the...

Страница 11: ...Date time The system date can be updated in this screen the system date is synchronized with the operating system Windows Date and time are only used for the datalogger function Switch The relays are...

Страница 12: ...l damages caused including negligence arising out of or in connection with the use or the inability to use the product The user has been advised by Elbro of the possibility of such damages Neither Elb...

Страница 13: ...ter a four digit password to be able to send SMS commands The default password is made up of four zeroes 0000 Please refer to the SMS commands section to get an overview of all available commands Enab...

Страница 14: ...rs who can work in case of failure It allows sending sequentially the digital input alarming messages observing the order found on the list of users with a time in terval default 5 minutes that can be...

Страница 15: ...correctly set the dip switch considering the chosen sensor Type of sensor Selection of the type of the sensor probe for example PT100 or PT1000 Conversion table In this table all desired values can b...

Страница 16: ...h a customizable text message On this mask the message text for each relay can be individually configured Response message The relay can only be controlled by SMS commands If you send a command to swi...

Страница 17: ...tivating at the same time the system it is connected to This function can be set through the following modes Exchange simple relay exchange is done ON OFF Pulse a programmable pulse of 1 up to 65535 s...

Страница 18: ...form this function the device is equipped with two super capacitors they require at least 30 minutes charging before any SMS can be sent The charge status can be viewed as a percentage in the System S...

Страница 19: ...a list of SMS commands with their relevant description and example Command Description Example PW R 1 4 0 deactivates relay outputs from 1 to 4 0000 R1 0 PW R 1 4 1 activates relay outputs from 1 to...

Страница 20: ...istive 2A 30V DC Maximum total load applicable to the device 10A Inputs SMSB242 4 p free contact digital inputs SMSB482 8 potential free contact digital inputs 2 analogue inputs 0 10V 0 20mA PT100 PT1...

Отзывы: