40
GENERAL
•
The connection to the electrical
network must be carried out by
qualified personnel and must be
according to existing norms.
•
The appliance must be connected to
the electrical network verifying above
all that the voltage corresponds to the
value indicated on the specifications
plate and that the cables section of
the electrical plant can bear the load
which is also indicated on the plate.
•
If the appliance is supplied without a
power supply plug and if you are not
connecting directly to the mains, a
standardized plug suitable for the load
must be fitted.
•
The colours of the wires in the
appliance power cable may not
correspond with the colours marked
on the terminals of your electrical plug/
fuse spur outlet. For the connection
proceed as follows:
— The wire which is coloured green
and yellow must be connected
to the terminal which is marked
with letter
E
or by the (Earth)
symbol or coloured green and
yellow.
— The wire which is coloured blue
must be connected to the terminal
which is marked with the letter
N
(Neutral) or coloured black.
— The wire which is coloured brown
must be connected to the terminal
which is marked with letter
L
(Live) or coloured red.
•
The bi-polar plug must be connected to
an outlet connected to the grounding
unit in conformity to security norms.
•
If the oven is to be connected directly
to the mains, it must be placed with
an omnipolar switch with minimum
opening between the contacts of 3 mm
between the appliance and the mains.
•
The power supply cable must not touch
the hot parts and must be positioned
so that it does not exceed 75°C at any
point.
•
Once the oven has been installed,
the switch or socket must always be
accessible.
•
If the power supply cable is damaged it
must be substituted by a suitable cable
available in the after sales service.
N.B. For connection to the mains, do
not use adapters, reducers or branching
devices as they can cause overheating
and burning.
If the installation requires alterations to the
domestic electrical system call an expert.
He should also check that the domestic
electrical system is suitable for the power
absorbed by the appliance.
Before effecting any intervention on
the electrical parts the appliance must
be disconnected from the network.
The connection of the appliance to the
grounding unit is mandatory.
The manufacturer declines every
responsability for any inconvenience
resulting from the inobservance of this
condition.