IMPORTANT NOTE:
LIGHTING GAS BURNERS FITTED
The device shall not be operated for
WITH SAFETY VALVE DEVICE
more than 15 seconds. If after 15
To ignite the burners, the following
seconds the burner has not lit, stop
instructions are to be followed:
operating the device and wait at least 1
minute before attempting a further
Press in the corresponding knob and turn
ignition of the burner.
counter-clockwise to the fu
until the flame has been lit (Fig. 2.2).
Press the electronic ignition push-button;
in the case of a mains failure light the
burner with a match or lighted taper.
Wait for about ten seconds af er the gas
burner has been lit before letting go of the
knob (valve activation delay);
Adjust the gas valve to the desired
position.
If the burner flame should go out for some
reason, the safety valve will automatically
stop the gas flow.
To re-light the burner,
return the knob to
the closed position, wait for at least 1
minute
and repeat the operations for
lighting.
If your local gas supply makes it difficult to
light the burner with the knob set to
maximum, set the knob to minimum and
repeat the operation.
!
!
!
!
ll flame
position marked by the “ ful l on”
symbol (Fig. 2.1) and hold the knob in
t
6
Fig. 2.2
Fig. 2.3