33
INSTALLATION
7
The installation conditions, concerning protection against overheating of the surfaces adja-
cent to the cooker, must conform to Figs. 7.1 or 7.2.
The appliance must be kept no less than 200 mm away from any side wall which exceeds
the height of the hob surface (Figs. 7.1 or 7.2).
The veneered syntetical material and the glue used must be resistant to a temperature of
90°C in order to avoid ungluing or deformations.
Curtains must not be fitted immediatly behind appliance or within 500 mm of the sides.
If the cooker is located on a pedestal it is necessary to provide safety measures to prevent
falling out.
The appliance must be hou-
sed in heat resistant units.
The walls of the units must
not be higher than work top
and must be capable of resi-
sting temperatures of 75 °C
above room temperature.
Do not instal the appliance
near inflammable materials
(eg. curtains).
■
Class 1
(Fig. 7.1a)
Gas connection made using
rubber hose which must be
visible and easily inspected
or using rigid or flexible metal
pipe.
A space of at least 2 cm must
be left between the cooker and
any adjacent furniture, which
must not exceed the height of
the cooktop.
■
Class 2
■
Subclass 1
(Fig. 7.1b)
Gas connection made using ri-
gid or flexible metal pipe.
Fig. 7.1b
Fig. 7.1a
650 mm
450 mm
200 mm
500 mm
450 mm
20 mm
20 mm
650 mm
500 mm
200 mm