X Motor stalled
1507
Problem X motor. Check the connections and functionality.
Replace the X motor or cable if needed.
See : "Troubleshoot".
X Motor overcurrent
1508
Problem X motor. Check the connections and functionality.
Replace the X motor or cable if needed.
See : "Troubleshoot".
X Motor switch Error
1509
Check if the switches are operating correctly.
X Motor firmware Error
1514
Please POWER OFF the machine - Contact Elaut NV.
Y motor calibration Error
1600
The calibration of the Y motor could not be completed.
Z motor calibration Error
1601
The calibration of the Z motor could not be completed.
Y Motor stalled
1612
Problem Y motor. Check the connections and functionality.
Replace the Y motor if needed. See : "Troubleshoot".
Y Motor overcurrent
1613
Problem Y motor. Check the connections and functionality.
Replace the Y motor if needed. See : "Troubleshoot".
Y Motor switch Error
1614
Check if the switches are operating correctly.
Y Motor wrong direction
1615
Problem Y motor. Check the connections and functionality.
Replace the Y motor if needed. See : "Troubleshoot".
Y Motor encoder Error
1616
Problem Y motor. Check the connections and functionality.
Replace the Y motor if needed. See : "Troubleshoot".
Y Motor I2C comms Error
1617
Problem Y motor. Check the connections and functionality.
Replace the Y motor if needed. See : "Troubleshoot".
Y Motor calibration timeout
1618
Problem Y motor. Check the connections and functionality.
Replace the Y motor if needed. See : "Troubleshoot".
Y Motor firmware Error
1619
Please POWER OFF the machine - Contact Elaut NV.
Z Motor switch Error
1626
Problem Z motor. Check the connections and functionality.
Z Motor calibration timeout
1630
Problem Z motor. Check the connections and functionality.
Loadcell not connected or overloaded
1631
Check the connections and functionality of the loadcell
and replace if needed.
Z motor movement timeout
1633
Check if the gantry can move freely, all switches are
adjusted correctly and no cables are broken.
Grab communication Error
1650
There’s a communication problem with the grabber
detected which can be caused by a bad cable or bad
grabber PCB.
Grab coils overheated
1664
Let the claw cool off before putting the machine in action
again.
Grab coil 1 not connected
1665
Check the connections of coil 1.
Grab coil 2 not connected
1666
Check the connections of coil 2.
Grab coil 3 not connected
1667
Check the connections of coil 3.
Grab coil 4 not connected
1668
Check the connections of coil 4.
Grab firmware Error
1669
Please POWER OFF the machine - Contact Elaut NV.
Movement timeout on X
1700
Check if the gantry can move freely, all switches are
adjusted correctly and no cables are broken.
Movement timeout on Y
1701
Check if the gantry can move freely, all switches are
adjusted correctly and no cables are broken.
No video capture device available
1800
Check the connections of the USB sticks (3) and replace if
needed.