3.2
AREA
Depending the general parameter “Number of areas”, up to 4 areas are listed in the group objects.
Each area can be controlled by using the 3 group objects: Arm, partial arm or disarm. Several statuses
are available and have a dedicated group object.
CONTROL OBJECT
VALUE ON
VALUE OFF
Arm (switch)
Arm
Disarm
Partial arm (switch)
Partial Arm
Disarm
Disarm (trigger)
Disarm
Disarm
For each area, a tab is made visible to configure the area parameters.
Areas are configured for areas 1 to 4 of the alarm system but by changing the parameter “Area
mapping” it is also possible to cover the areas 5 to 8.
A scene can be assigned to each status. This scene number will be recalled each time the zone status is
active (ON).
Leave the scene number to 0 to disable the scene control.
STATE
SCENE
Disarmed
0..64
Entry
0..64
Exit
0..64
Armed
0..64
Partial armed
0..64
Fire alarm
0..64
Siren ON (Audible alarm)
0..64
Panic alarm (Silent alarm)
0..64
Intrusion alarm
0..64