S A F E T Y   G U I D E L I N E S  

This  fixture  is  an  extremely  sophisticated  piece  of  electronic  equipment.  To  guarantee a 
smooth operation, it is important to follow all instructions and guidelines in this manual. The 
manufacturer of this device is not responsible for injury and/or damages resulting from the 
misuse of this fixture due to the disregard of the information printed in this manual. Only 
qualified and/or certified personnel should perform installation of this fixture and only the 
original  rigging  parts  (omega  brackets)  included  with  this  fixture  should  be  used  for 
installation. Any modifications to the fixture and/or the mounting hardware included will void 
the original manufactures warranty and increase the risk of damage and/or personal injury. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

DO  NOT  TOUCH

  the  fixture  housing  during  operation.  Turn  OFF  the  power  and  allow 

approximately 15 minutes for the fixture to cool down before serving. 

DO NOT

 shake fixture, avoid brute force when installing and/or operating fixture. 

DO NOT

 operate fixture if the power cord has become frayed, crimped, damaged and/or if 

any of the power cord connectors are damaged and do not insert into the fixture securely 
with ease. 

NEVER

 force a power cord connector into the fixture. If the power cord or any of 

its connectors are damaged, replace it immediately with a new one of similar power rating. 

DO NOT 

block air ventilation slots. All air/fan inlets must remain clean and never blocked. 

Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling. 
When installing fixture in a suspended environment, always use mounting hardware that is no 
less than M10 x 25 mm, and always install fixture with an appropriately rated safety cable. 
Always disconnect fixture from main power source before performing any type of service 
and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the 
plug by tugging the wire portion of the cord. 
During the initial operation of this fixture, a light smoke or smell may emit from the interior of 
the fixture. This is a normal process and is caused by excess paint in the interior of the casing 
burning off from the heat associated with the lamp and will decrease gradually over time.   
Consistent operational breaks will ensure fixture will function properly for many years. 

PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED 

DO NOT PLUG FIXTURE INTO A DIMMER PACK! 
NEVER OPEN THIS FIXTURE WHILE IN USE! 
UNPLUG POWER BEFORE SERVICING FIXTURE! 
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT! 
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE! 
 
INDOOR / DRY LOCATIONS USE ONLY! 
DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE! 
 
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! 
RETINA INJURY RISK - MAY INDUCE BLINDNESS! 
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK! 

Содержание WW PROFILE HP

Страница 1: ...WW PROFILE HP user manual EL AT IO N WW PROFILE HP user manual...

Страница 2: ...in this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product ELATION PROFESSIONAL USA 6122 S Eastern Ave Los Angele...

Страница 3: ...mited Warranty USA Only 5 Safety Guidelines 6 Maintenance Guidelines 7 Fixture Overview 8 Lens and Gobo Holder Installation 9 Fixture Installation 10 System Menu 12 DMX Channel Functions And Values 19...

Страница 4: ...dealer without first contacting customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Power Cable Safety Cab...

Страница 5: ...penses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the p...

Страница 6: ...ed replace it immediately with a new one of similar power rating DO NOT block air ventilation slots All air fan inlets must remain clean and never blocked Allow approx 6 15cm between fixture and other...

Страница 7: ...ized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed ele...

Страница 8: ...DOWN Button 5 MODE ESC Button 6 ENTER Button 7 LCD Menu Control Display 8 FUSE 9 5pin DMX IN 10 3pin DMX IN 11 3pin DMX OUT 12 5pin DMX OUT 13 powerCON TRUE1 IN 14 powerCON TRUE1 OUT 15 Mounting Yoke...

Страница 9: ...9 L E N S A N D G O B O H O L D E R I N S T A L L A T I O N Gobo Holder not included Supports B Size Metal and HT Transparency Gobos not included...

Страница 10: ...m matrix designs to any metal truss structure or placing the fixture s on any surface a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is prope...

Страница 11: ...ty cable rigging point RIGGING Overhead rigging requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety inspection o...

Страница 12: ...erent functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN bu...

Страница 13: ...ock ON OFF LCD Control Panel Key Lock Temp C F Cels Fahren Temperature Switch Between C F Man Hold ON OFF Keep Man Settings When Power Loss Refresh Fq 900 1200 1500 2 5K 4K 5K 6K 10K 15K 20K 25K Refre...

Страница 14: ...e DMX value of Channel 2 on the controller to 7 or 8 When set to 7 the DMX address can be set between 1 and 255 When set to 8 the DMX address can be set between 256 and 511 4 Using Channel 3 on the co...

Страница 15: ...one of the 10 user defined internal Auto Programs EditProg EditProg Edit any of the 10 user defined internal Auto Programs EditProg EditScen Edit any of the 250 scenes of the internal Auto Programs E...

Страница 16: ...to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 To start an Auto Program proceed as follow...

Страница 17: ...its Press ENTER to confirm Press MODE ESC in order to return to the main menu 4 Program Selection for Edit Program Select Edit Program Press ENTER to confirm Select Edit Program Press ENTER to confirm...

Страница 18: ...e Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 Th...

Страница 19: ...NCTION 1CH 4CH 1 1 DIMMER 0 255 Intensity 0 to 100 2 DIMMER FINE 0 255 FINE Intensity 0 to 100 3 STROBE 0 31 LED OFF 32 63 LED ON 64 95 Strobe Effect SLOW to FAST 96 127 LED ON 128 159 Pulse Effect In...

Страница 20: ...sparency Gobos static gobo holder not included CONTROL CONNECTIONS 2 DMX Channel Modes 1 4 Adjustable Refresh Rate Adjustable Gamma Brightness 4 Button Control Panel LED Menu Display 3 5pin DMX In Out...

Страница 21: ...ses and can radiate radio frequency energy and if not installed and used in accordance with the included instructions may cause harmful interference to radio communications However there is no guarant...

Страница 22: ...22 DIMENSIONAL DRAWINGS Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice...

Страница 23: ...Profile High Definition Lens 19 PHD126 Profile High Definition Lens 26 PHD236 Profile High Definition Lens 36 PHD350 Profile High Definition Lens 50 AC3PDMX5PRO 5 ft 1 5m 3pin PRO DMX Cable AC5PDMX5PR...

Страница 24: ......

Отзывы: