21
SYSTEM MENU CHANGE WITH SOFTWARE UPDATE VERSION
≥
1.0.10
See highlighted menu items below which have been updated with this software update.
Features are subject to change without any prior written notice.
MAIN MENU
SUB MENU
OPTIONS / VALUES
(Default Settings in
BOLD
)
DESCRIPTION
FUNCTION
Set Dmx Address
A001~AXXX
DMX Address Setting
Dmx Value
ALL……
DMX Value Display
Slave Mode
Slave1, Slave2, Slave3
Slave Setting
Auto Program
Master / Alone
Auto Program
INFORMATION
Time Information
Current Time
XXXX (Hours)
Fixture Run Time From Power ON
Total Run Time
XXXX (Hours)
Fixture Total Run Time
Last Run Time
XXXX (Hours)
Clear Fixture Last Run Time
LastRun Password
Password=XXX
Password
038
Clear Last Run
ON /
OFF
Clear Fixture Last Run Time
Temperature Info
Head Temperature
XXX C° /
F °
Temperature in Fixture Head
Ethernet IP
XXX.XXX.XXX.XXX
Fixture IP Address
XXX.XXX.XXX.XXX
Fan Speed
1U_Fan1: ~ 5U_Fan2:
XXX RPM
Fan Speeds
Software Version
1U01: - 7U01:
≥
V1.0.10
Software Version
Error Info
Error Record 1 ~ Error Record 10
Pan....
PERSONALITY
Status Settings
Address via DMX
ON
/OFF
Address Via DMX
No DMX Status
Close Shutter /
Hold
/
Auto Program
Auto Run If No DMX
Pan Reverse
ON/
OFF
Pan Reverse Movement
Tilt Reverse
ON/
OFF
Tilt Reverse Movement
Pan Degree
630/
540
Pan Degree Select
Feedback
ON
/OFF
Movement Feedback
Movement Speed
Speed
1
~ 4
Movement Mode Select
Fast Mode
ON/
OFF
Fast Mode Select
Hibernation
OFF, 01M~99M,
15M
Stand By Mode
Dimmer Mode
Standard
, Stage, TV,
Architectural, Theatre
Set Dimmer Curve Mode
Service Setting
Password
Password=
050
Service Password
RDM PID
XXXXX
RDM PID Code
(PSWD Required)
Ethernet IP
XXX . XXX . XXX . XXX
Ethernet IP
(PSWD Required)
Ethernet Mask IP
XXX . XXX . XXX . XXX
Ethernet Mask IP
(PSWD Required)
Clear Err. Info
ON/
OFF
Clear Error Info
(PSWD Required)
Fans Control
Auto
, Silent
Select Fans Mode
Display Setting
Shutoff Time
02~60m
05m
Display Shut Off Time
Display Reverse
ON/
OFF
Display Reverse 180º
Key Lock
ON/
OFF
Key Lock
Temperature C/F
Celsius/
Fahrenheit
Temperature Switch Between C˚/ F˚
Initial Status
PAN =XXX
Initial Effect Position
Refresh
1200
, 900-1500, 2500, 4000, 5000, 10000,
15000, 20000, 25000 (Hz)
Refresh Frequency Rate Setting
Gamma
Gama =
2.0
, 2.2, 2.4, 2.8
Gamma Setting
Select Signal
DMX Only
DMX Only
Art-Net
Select Art-Net
sACN
Select sACN
Set Universe
000
- 32767
Set ArtNet Universe
Reset Default
ON/
OFF
Password=
011
Restore Factory Settings
(PSWD Required)
Содержание SATURA PROFILE
Страница 1: ...SATURA PROFILE user manual...
Страница 40: ......