3.11 Error and Information Messages
HEAt
This message appears if you try to switch on the lamp within 5
minutes after having switched off (lamp too hot). The message
will appear on the display if the lamp doesn’t ignite within 20
seconds. The fixture will store this command and automatically
ignite the lamp after 5 minutes.
LaeR
After two unsuccessful lamp ignition attempts the display will
readout
LAER
. This means the lamp could be damaged, the
lamp is missing, the fixture is overheating, or there could be a
failure on the igniter or ballast.
OTMP
This error message informs you the fixture was overheating and
the protective relay switched off the lamp. Please look for
possible reasons (fan faulty, air in/outlets blocked or very dirty,
lamp broken or very old, too high ambient temperature. Switch
off the power supply and solve the possible problem.
RsER
This message informs you one of the fixtures function was
unable to reset properly (magnetic sensor, stepping motor,
driver on the PCB, cables, etc.). Repair the defect and start the
fixture again.
4 Operation
Operating Modes: The Power Wash 250™ can operate in three different modes. This
next section will detail the differences in the operating modes.
• Stand alone mode -
The fixture will react to sound, chasing through the built-in programs.
• Master/Slave mode -
You can daisy chain up to 16 fixtures together to get a synchronized light show without
the need of an external controller. The fixtures will react to sound chasing to
synchronized light show.
• DMX control mode -
This function will allow you to control each individual fixtures traits with a standard
DMX-512 controller such as the LSC
®
Show Designer 2.
™
Universal DMX Control:
This function allows you to use a universal DMX-512
controller such as the LSC
®
DMX Operator II™ or LSC
®
Show Designer 2™ to control