Power Wash 250™
©Elation Professionals® Los Angeles, Ca. 90058 -
www.ElationLighting.com
-
Page 22
PAN
0 - 255
Pan Position
TILT
0 - 255
Tilt Position
CYAN
0 - 255
Cyan color wheel
MAGE
0 - 255
Magenta color wheel
YELL
0 - 255
Yellow color wheel
COLO
0 - 255
Color wheel (fixed colors)
SHUT
0 - 255
Shutter / Strobe function
DIMR
0 - 255
Dimmer
FOCU
0 - 255
Focus
SPEC
0 - 255
Lamp Off, Reset, ...
Display
(DISP)
DISP
Use this function to choose between different display indications. Use the
Up
and
Down
buttons to toggle between the two different display modes.
Press
Enter
to confirm or
Mode
to cancel and return to the menu.
D ON
Display On/Off (If you've chosen
off
, the display will go out with-
in 15 seconds after the last input. The next key touch will
reactivate the display).
REV
Turn around the display
3.10.5 Fixture Temperature
(TEMP)
TEMP
This function allows you to read out the actual temperature of the fixture.
Press
Enter
to confirm or
Mode
to cancel. Inside temperatures below
80°C are not critical. Temperatures above 80°C will send the fixture into
protect mode and automatically switch the lamp off. Please note for a safe
operation the outside temperature should not exceed 45°C.
3.10.6 Fan Control
(FANS)
FANS
By using this function you can choose between 4 types of fan speed