User Manual
Software Version 1.19 Revised 10/2003
Страница 1: ...User Manual Software Version 1 19 Revised 10 2003...
Страница 2: ...Power Wash 250 Elation Professionals Los Angeles Ca 90058 www ElationLighting com Page 2...
Страница 3: ...cure the POWER WASH 250 12 2 3 Connections 13 2 3 1 Power Supply 13 2 3 2 DMX 13 2 4 Fuse 15 3 The Menu Field 16 3 1 DMX Addressing D001 18 3 2 Audio Mode AUDI 18 3 3 Test Mode TEST 18 3 4 Lamp On Off...
Страница 4: ...4 3 10 11 Correction of faults EFLD 24 3 11 Error and Information Messages 24 5 Operation 25 DMX Operation 25 Stand Alone Operation 25 Master Slave Operation 26 4 DMX Channel Selection DMX Protocol 27...
Страница 5: ...o operate the fixture have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this fixture to...
Страница 6: ...not covered under warranty conditions This fixture emits intense UV radiation which is harmful to the eyes and skin The intense luminance of the lamp can cause severe damage to the retina Never opera...
Страница 7: ...revent personal injury never touch the lamp if you are not absolutely sure it has cooled 5 Never look directly into the lamp beam You risk injury to your retina which may induce blindness 6 Be sure to...
Страница 8: ...y 1 0 Firmware Connection 1 1 Microphone Sensitivity 12 DMX Input Jack 13 DMX Output Jack 14 Power On Off Switch 15 Fuse Holder 16 Fan air inlet Max Min DMX IN DMX OUT Software Update 1 G r oun d 2 D...
Страница 9: ...ng the fixture by head or yoke Pulling on or transporting the fixture by moving head may severely damage the fixture and will void the fixture warranty 5 Up Button This button is used to scroll forwar...
Страница 10: ...3 15 amp 220v GMA protective fuse Never defeat the fuse the fuse is designed to protect the electronics in the event of sever power fluctuations Always be sure to replace the fuse with an exact match...
Страница 11: ...times the weight of the fixture Never use the carrying handles for secondary attachment Refer to regulations BGV C1 former VBG 70 and DIN VDE 0711 217 for proper installation in Europe To ensure prope...
Страница 12: ...r M6x20 screws 1 2 Securing the POWER WASH 250 Regardless of the rigging option you choose for your POWER WASH 250 always be sure to secure your fixture with a safety cable The fixture provides a buil...
Страница 13: ...xture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of di...
Страница 14: ...ield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior 1 7 Special Note Line Termination When longer runs of cable are used...
Страница 15: ...model or 230V T 3 15A EU model The fuse requirements are clearly printed on the side of the fixture WARNING Always disconnect main power before changing a fuse Always replace with the exact same type...
Страница 16: ...address TEST Activates the fixtures self test mode AUDI ASLW Activates Sound Active mode slow AFST Activates Sound Active mode fast MSTR Runs fixture as Master for audio master slave mode SVPT Runs fi...
Страница 17: ...he calibration menu with technician code for authorized person only COLO Calibration of the color wheel BSPR Calibration of the beam shape clre Settings in the internal memory technician only facc Mus...
Страница 18: ...git address is flashing use the Up and Down buttons to select adjust the address Lock your new address into by pressing the Enter button After the new address has been successfully stored into the fix...
Страница 19: ...RESE This function will rest and return all motors to the home position Access the reset function in the main menu and press the Enter button to engage the reset function RST will readout in the displ...
Страница 20: ...r button to accept the change or the Mode button to cancel and return to the main menu 3 10 Special Functions SPEC SPEC This menu option accesses several special features and function of the POWER WAS...
Страница 21: ...e the lamp through a DMX controller you must turn this function off To toggle between Off and ON use the Up and Down buttons Use the Enter button to confirm your setting Please note ON is the default...
Страница 22: ...ress Enter to confirm or Mode to cancel and return to the menu D ON Display On Off If you ve chosen off the display will go out with in 15 seconds after the last input The next key touch will reactiva...
Страница 23: ...ate at the lowest speed When the maximum internal intolerable operating temperature is reached the fan will automatically switch from low to high speed 3 10 7 Adjustments and Calibrations ADJU ADJU Wi...
Страница 24: ...ilt reverse RTLT ON OFF Automatic lamp on LAAU ON OFF Lamp on via DMX DLOF ON OFF Display DISP D ON Cooling fan FANS HIGH REG LOOF LOHI Feedback FEED ON OFF 3 10 9 Feedback FEED FEED The POWER WASH 25...
Страница 25: ...old too high ambient temperature Switch off the power supply and solve the possible problem RsER This message informs you one of the fixtures function was unable to reset properly magnetic sensor step...
Страница 26: ...elp operating in DMX mode consult the manual included with your DMX controller Stand Alone Operation Sound Active This mode allows a single fixture to run to the beat of the music Only use this mode w...
Страница 27: ...ctor is the input and the Female XLR connector is the output The first fixture in the chain master will use the female XLR connector only The last fixture in the chain will use the male XLR connector...
Страница 28: ...ast slow CCW max 2 9 turns sec 192 25 3 C0 FD 76 98 Audio color chaser slow each 4 th sound impulse new color 254 FE 99 Audio color chaser fast each sound impulse new color 255 FF 100 6 Cyan Cyan colo...
Страница 29: ...28 29 1C 1D 11 2 4 270 30 31 1E 1F 12 TILT size phase see also PAN 32 63 20 3F 13 25 PAN TILT size phase see also PAN 64 95 40 5F 26 37 PAN TILT inverse size phase see also PAN 96 127 60 7F 38 50 Circ...
Страница 30: ...s allow ample time for the fixture to cool approximately 20 minutes before attempting a lamp change Never handle lamp with your bare hands as the oils from your skin may damage the lamp Be sure to rev...
Страница 31: ...intensity The minimum deviation amount is 1 0mm Running the fixture within a lower deviation can cause damage to the lamp and or lens The POWER WASH 250 lamp holder is aligned at the factory However d...
Страница 32: ...nt Locate and remove the unit s power cord from the main power supply Once the cord has been removed located the fuse holder located on the side panel of the near the power Using a flat head screwdriv...
Страница 33: ...t cloth and glass cleaning fluid Lamp Never Moveable parts Yearly suitable fatty oil The above chart is a recommended cleaning schedule only Cleaning frequency depends on the environment in which the...
Страница 34: ...rocedures 3 Open and remove the upper half of the projector by loosening the 4 retaining Phillips screws Two on the front side and 2 on the backside of the head 4 Follow the chart above to complete th...
Страница 35: ...Power Wash 250 Elation Professionals Los Angeles Ca 90058 www ElationLighting com Page 35 Power Wash Color Wheel Orientation...
Страница 36: ...Beam shape Continuously Beam shape Frost filter Mechanically adjustable Beam angel 8 22 Shutter Strobe Dimmer Strobe effect variable in speed 1 10 flashes per second Continuously mechanical dimmer 0 1...
Страница 37: ...ge to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which Elation Professionals...
Страница 38: ...pressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or repla...
Страница 39: ...24 F Fan Controls 22 Fuse Replacement 32 I Introduction 5 Inverting Pan Movements 19 Inverting Tilt Movements 20 L Lamp Change 30 Lamp Optimization 31 Lamp ON Manual 19 Lamp ON Automatic 21 Lamp OFF V...
Страница 40: ...Elation Professional 4295 Charter Street Los Angeles CA 90058 323 582 3322 323 582 3108 fax www ElationLighting com info ElationLighitng com...