Preparations before operation
Warning!
The installation should be done by qualified staff only.
1. Unpack the shipping container carefully, assemble the accessories
to fit in their right positions for proper attachment.
2. This unit can be hung or placed in any safe, secure surface by means
of its adjustable mounting bracket.
3. When you are sure this unit is ready for operation, plug this unit into
the appropriate AC outlet.
First time setup
Lens Focusing
1. Hang the fixture in your final desired position.
2. Loosen the thumb screw fitted in the lens support that hold the lens
in place.
3. Adjust the lens by turning it in a clockwise or counter-clockwise
direction until you reach proper focus.
4. Tighten the thumb screw after you achieve your desired focus.
Cleaning
1. Disconnect the fixture from AC power and allow the fixture to cool
down completely.
2. Use normal glass cleaner and a soft cloth to wipe down the outside
casing and external lens.
3. Use only soft cloth to clean the internal optics.
4. Always be sure to dry all parts completely before plugging in.
Secure the Image Pro 300 II. Regardless of the rigging of the Image Pro 300 II,
you have to use a safety wire to fix your fixture. Therefore you have to thread to
safety wire through one provided holes on the yoke and connect it with the truss
for tree mounting application. Pay attention to a safe and proper fastening.
Securing the Image Pro 300 II
Caution:
Install a safety chain/cord that can hold at least 10 times the weight of the fixture.
Never use the carrying handles for attachment.
-5-
Lamp Replacement
Metal Halide Lamp Warning!
This fixture is fitted with a metal halide lamp which is highly susceptible to
damage if improperly handled. Do not touch the bulb of the lamp with bare
fingers(this can cause damages). The lamp contains small quantities of
materials that will be harmful to the environment, please dispose of the
damaged lamp properly.
To replace the lamp
1. Disconnect the fixture from power and allow the lamp to cool.
2. Loosen the two knurled screws and remove the top cover.
3. Loosen the 2 thump screws from the lamp socket.
4. Gently take the old lamp out.
5. Replace the new lamp and refit the 2 thumb screws.
6. Put in the new lamp securely into the socket. Please note the protuberance
of bulb shall be upward orientation to obtain equal intensity distribution
(see figure).
7. Tighten the 2 thumb screws and reassemble in reverse order.
Upright upward
Remember: Do not touch the lamp with your bare fingers.
-6-