background image

Preparations before operation

Warning!

The installation should be done by qualified staff only.

1. Unpack the shipping container carefully, assemble the accessories

to fit in their right positions for proper attachment.

2. This unit can be hung or placed in any safe, secure surface by means

of its adjustable mounting bracket.

3. When you are sure this unit is ready for operation, plug this unit into

the appropriate AC outlet.

First time setup

Lens Focusing

1. Hang the fixture in your final desired position.
2. Loosen the thumb screw fitted in the lens support that hold the lens

in place.

3. Adjust the lens by turning it in a clockwise or counter-clockwise

direction until you reach proper focus.

4. Tighten the thumb screw after you achieve your desired focus.

Cleaning

1. Disconnect the fixture from AC power and allow the fixture to cool

down completely.

2. Use normal glass cleaner and a soft cloth to wipe down the outside

casing and external lens.

3. Use only soft cloth to clean the internal optics.
4. Always be sure to dry all parts completely before plugging in.

Secure the Image Pro 300 II. Regardless of the rigging of the Image Pro 300 II,
you have to use a safety wire to fix your fixture. Therefore you have to thread to
safety wire through one provided holes on the yoke and connect it with the truss
for tree mounting application. Pay attention to a safe and proper fastening.

Securing the Image Pro 300 II

Caution:

Install a safety chain/cord that can hold at least 10 times the weight of the fixture.
Never use the carrying handles for attachment.

-5-

Lamp Replacement

Metal Halide Lamp Warning!

This fixture is fitted with a metal halide lamp which is highly susceptible to
damage if improperly handled. Do not touch the bulb of the lamp with bare
fingers(this can cause damages). The lamp contains small quantities of
materials that will be harmful to the environment, please dispose of the
damaged lamp properly.

To replace the lamp

1. Disconnect the fixture from power and allow the lamp to cool.
2. Loosen the two knurled screws and remove the top cover.
3. Loosen the 2 thump screws from the lamp socket.
4. Gently take the old lamp out.
5. Replace the new lamp and refit the 2 thumb screws.
6. Put in the new lamp securely into the socket. Please note the protuberance

of bulb shall be upward orientation to obtain equal intensity distribution
(see figure).

7. Tighten the 2 thumb screws and reassemble in reverse order.

Upright upward

Remember: Do not touch the lamp with your bare fingers.

-6-

Содержание IMAGE PRO 300 II

Страница 1: ...a l A c c e s s o r ie s L E N s S e r ie s Order Code Model Descriptions 28 002 0249 00 26 020 0020 00 28 003 0069 00 26 007 0036 00 28 003 0066 00 28 003 0050 00 26 007 0035 00 ISP F1 ISP F1R IP F3 R IP 2 ISP RGW ISP FM IP 3 Static slide holder Rotating slide suppor t Manual or timed tri slide changer Rotating gobo holder Rotating gobo wheel Manual fixed mirror Motorized mirror TYPE H I J Order ...

Страница 2: ...on Fuse Slow acting Cooling Optional Accessories Included 555x240x262mm 10 5Kg HTI 300W DEL lamp 85V 300W 750hours AC 100 120V 50 60Hz 450 Watts maximum T6 3A 250V 5x20mm Forced air with axial fan One fixed gobo holder 6 metal gobos One fixed lens holder 1 2 4 100mm single element lens All rights reserved Improvement and changes to specifications design and this user s manual may be made at any ti...

Страница 3: ...or damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all equipment necessary to operate the unit has arrived intact In the event damage has been found or parts are missing contact technical support for further instructions Do not return the unit to your dealer without contacting technical support first Servic...

Страница 4: ...e range of optional static or motorized accessories in the Image Pro 300 II together with a special zoom lens and various dedicated static or motorized accessories The effects can be static and dynamic for fixed presentations The Image Pro 300 II is equipped with filters and additional systems to prevent the slides from overheating Atypical use of the Image Pro 300 II projector is for attracting a...

Страница 5: ...n 2 Check that the local power outlet match that of the required voltage of your unit 3 Plug this unit into the AC power outlet turn the switch on 4 The lamp will be lit and the cooling fan will start immediately Important Never disconnect or reconnect the power frequently during operation this will shorten the lamp life Wait at least 10 minutes to cool down the lamp completely before restarting t...

Страница 6: ...you have to use a safety wire to fix your fixture Therefore you have to thread to safety wire through one provided holes on the yoke and connect it with the truss for tree mounting application Pay attention to a safe and proper fastening Securing the Image Pro 300 II Caution Install a safety chain cord that can hold at least 10 times the weight of the fixture Never use the carrying handles for att...

Отзывы: