Elation Professional - www.elationlighting.com - EPAR QA Instruction Manual Page 13
Elation Professional - www.elationlighting.com - EPAR QA Instruction Manual Page 14
Channel 1, 2, 3, & 4 will not work, when Channel 5 is being
used.
Channel 8 is the dimmer curve setting, please see the Dimmer
Curve Diagram Chart on page 17 to see the settings and their
respective beginning and ending fade times.
EPAR QA 8 Channel Mode - DMX Values and Functions
Channel Value
Function
1 RED
0 - 255 0% - 100%
2 GREEN
0 - 255 0% - 100%
3 BLUE
0 - 255 0% - 100%
4 AMBER
0 - 255 0% - 100%
5 1 - 255 COLOR MACROS
PLEASE SEE 1 CHANNEL MODE
6 0 - 15 NOTHING
16 - 255 STROBING/SPEED CONTROL
7 MASTER DIMMER
0 - 255 0% - 100%
8 DIMMER CURVE SETTING
0 - 20 DR-0 SETTING
21 - 40 DR-1 SETTING
41 - 60 DR-2 SETTING
61 - 80 DR-3 SETTING
81 - 100 DR-4 SETTING
101 - 255 DIMMER CURVE SETTING IS ACTIVE
Channel Value
Function
1 RED
0 - 255 0% - 100%
2 GREEN
0 - 255 0% - 100%
3 BLUE
0 - 255 0% - 100%
4 AMBER
0 - 255 0% - 100%
5 MASTER DIMMER
0 - 255 0% - 100%
6 DIMMER CURVE SETTING
0 - 20 DR-0 SETTING
21 - 40 DR-1 SETTING
41 - 60 DR-2 SETTING
61 - 80 DR-3 SETTING
81 - 100 DR-4 SETTING
101 - 255 DIMMER CURVE SETTING IS ACTIVE
EPAR QA 6 Channel Mode - DMX Values and Functions
Channel 6 is the dimmer curve setting, please see the Dimmer
Curve Diagram Chart on page 17 to see the settings and their
respective beginning and ending fade times.