![Elation EPAR QA Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/elation/epar-qa/epar-qa_user-instructions_2376152005.webp)
Elation Professional - www.elationlighting.com - EPAR QA Instruction Manual Page 10
Elation Professional - www.elationlighting.com - EPAR QA Instruction Manual Page 9
EPAR QA 1 Channel Mode - DMX Values and Functions
Channel Value
Function
1 COLOR MACROS
0 OFF
1 - 4 MACRO 1
5 - 8 MACRO 2
9 - 12 MACRO 3
13 - 16 MACRO 4
17 - 20 MACRO 5
21 - 24 MACRO 6
25 - 28 MACRO 7
29 - 32 MACRO 8
33 - 36 MACRO 9
37 - 40 MACRO 10
41 - 44 MACRO 11
45 - 48 MACRO 12
49 - 52 MACRO 13
53 - 56 MACRO 14
57 - 60 MACRO 15
61 - 64 MACRO 16
65 - 68 MACRO 17
69 - 72 MACRO 18
73 - 76 MACRO 19
77 - 80 MACRO 20
81 - 84 MACRO 21
85 - 88 MACRO 22
89 - 92 MACRO 23
93 - 96 MACRO 24
97 - 100 MACRO 25
101 - 104 MACRO 26
105 - 108 MACRO 27
109 - 112 MACRO 28
113 - 116 MACRO 29
117 - 120 MACRO 30
121 - 124 MACRO 31
125 - 128 MACRO 32
Master-Slave Operation:
This function will allows you to link units together to run in a Master-Slave
mode. In Master-Slave operation one unit will act as the controlling unit
and the others will react to the controlling units built-in programs. Any
unit can act as a Master or as a Slave however, only one unit can be pro-
grammed to act as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit.
Use standard XLR data cables to link your units together. Remem-
ber that the Male XLR connector is the input and the Female XLR
connector is the ouput. The first unit in the chain (master) will use
the female XLR connector only. The last unit in the chain will use the
male XLR connector only.
2. Set the “Master” unit to your desired mode or operation.
3. For the “Slave” unit(s), set the display to any DMX channel mode.
Example: Set the unit to 4 channel mode, the display should read
“3000” or any variables, i.e “3001”, “3002 etc..
4. Connect the “Slave” unit or units and they will automatically start to
follow the “Master.”
EPAR QA Master-Slave Configuration
Dimmer Curve Setting:
1. Plug the fixture in and press the MODE button until “dr-X” is dis-
played. “X” representing a number between 0-4.
2. There are 5 dimmer curve settings to choose from. Please see the
Dimmer Curve Diagram Chart on page 17 to see the settings and
their respective beginning and ending fade times.
Power Consumption Adjustment:
1. Plug the fixture in and press the MODE button until “PXXX” is dis-
played. “XXX” representing a number between 001-003.
2. “001” is the lowest power consumption, and “003” is highest power
consumption. To change the power consumption press the UP or
DOWN buttons for at least 15 seconds. See page 18 for a power
consumption setting chart.
NOTE: The power consumption setting will have a tiny effect on the out-
put intensity.
EPAR QA Operating Instructions